![Capintec CAPTUS 2000 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/capintec/captus-2000/captus-2000_owners-manual_494180019.webp)
CAPINTEC, INC
CAPTUS
®
2000
TECHNICAL SPECIFICATIONS
Pentium class computer system including the MS Windows
®
operating system with a
multichannel analyzer PC Board, two scintillation detectors, a dual input detector
preamplifier/switch PC Board, a trackball pointing device, a color printer, and exceptionally
easy to use CAPTUS
®
2000 application software.
Thyroid Uptake Stand
Rugged floor stand with heavy duty locking casters and an articulating arm for the positioning
of detector/collimator. Individual shelves provided for the CAPTUS
®
2000 computer / monitor
system / monitor and for the printer. Mounting for the isolation transformer and the optional
well detector is provided on the base of the floor stand.
Dimensions:
Height
175.3
cm
(69")
Width
71.1 cm
(28")
Depth
78.7 cm
(31")
Weight
181.8
kg
(400
lb.)
(with optional well)
213.6 kg
(470 lb.)
System Power Requirements
CAUTION
If the input voltage to the following items is not within the stated limits, the unit may not
function correctly or may be damaged.
Standard 115V*
105-127V 1.3
Amps 50/60Hz
Optional 100V*
90-110V 1.5
Amps 50/60Hz.
Optional 230V*
210-255V
0.8
Amps 50/60Hz.
Optional 200V*
180-220V
1.0
Amps 50/60Hz.
*(Transformer Voltage Taps are set at the factory.)
Environment Requirements
Operational
The instrument should be located where the level of the background radiation is as
low and as constant as possible.
The instrument should be located where the temperature is stable within a range of
+50°F to +85°F (+10°C to +30°C) and the maximum relative humidity is 90% non-
condensing to warrant maximum reliability and accuracy.
The instrument should be located where the barometric pressure is within a range of
27 – 31 inches of mercury (91 – 105 kilopascals).
July 00
FUNCTIONAL & TECHNICAL DESCRIPTION
2-3
Содержание CAPTUS 2000
Страница 2: ......
Страница 8: ......
Страница 26: ......
Страница 47: ...CAPINTEC INC CAPTUS 2000 Figure 4 16 July 00 SYSTEM SETUP 4 15...
Страница 48: ...CAPINTEC INC CAPTUS 2000 4 16 SYSTEM SETUP July 00...
Страница 52: ......
Страница 63: ...CAPINTEC INC CAPTUS 2000 Figure 5 9 July 00 QUALITY ASSURANCE 5 11...
Страница 66: ......
Страница 105: ...CAPINTEC INC CAPTUS 2000 Figure 7 10 July 00 WIPE TESTS 7 11...
Страница 133: ...CAPINTEC INC CAPTUS 2000 Figure 8 31 July 00 LAB TESTS 8 25...
Страница 145: ...CAPINTEC INC CAPTUS 2000 Figure 8 46 July 00 LAB TESTS 8 37...
Страница 157: ...CAPINTEC INC CAPTUS 2000 July 00 LAB TESTS 8 49 Figure 8 59...
Страница 158: ......
Страница 165: ...CAPINTEC INC CAPTUS 2000 Figure 9 7 July 00 BIOASSAY 9 7...
Страница 173: ...CAPINTEC INC CAPTUS 2000 July 00 BIOASSAY 9 15 Figure 9 17...
Страница 174: ......
Страница 190: ...CAPINTEC INC CAPTUS 2000 Figure 10 19 10 16 MCA July 00...
Страница 198: ...CAPINTEC INC CAPTUS 2000 10 24 MCA July 00 Figure 10 30...
Страница 204: ...CAPINTEC INC CAPTUS 2000 11 6 CLEANING AND MAINTENANCE July 00 Figure 11 2...