Chapter 16
16-45
<USER>
T-16-52
STNBY-TM
Use it to switch over the standby shift time.
setting
0: normal (default)
1: increase standby shift time until possibility of image distortion is absent
2
KSIZE-SW
for future use
2
COPIER > OPTION >USER
Sub-item
Description
Level
COPY-LIM
Use it to put an upper limit to the number of copies.
setting: 1 to 9999 (default: 9999)
1
SLEEP
Use it to enable/disable the sleep function.
setting
0: off
1; on (default)
1
WEB-DISP
Use it to enable/disable the fixing web length warning message.
setting
0: off (do not display)
1: on (display; default)
If set to '0', the message will only be on the service mode screen.
1
W-TONER
Use it to enable/disable the waste toner case full message.
setting
0: off (do not display)
1: on (display; default)
If set to '0', the message will be only on the service mode screen.
1
COUNTER1
Use it to set soft counter 1 of the user mode screen.
101: total 1 (fixed)
1
COUNTER2
Use it to set soft counter 2 of the user mode screen.
setting: 0 to 999
1
COUNTER3
Use it to set soft counter 3 of the user mode screen.
setting: 0 to 999
1
COUNTER4
Use it to set soft counter 4 of the user mode screen.
setting: 0 to 999
1
COUNTER5
Use it to set soft counter 5 of the user mode screen.
setting: 0 to 999
1
COUNTER6
Use it to set soft counter 6 of the user mode screen.
setting: 0 to 999
1
CONTROL
Use it to limit the use of the control card for PDL jobs.
setting
0: do not limit (default)
1: limit
1
B4-L-CNT
Use it to specify where B4 should be counted as large or small size for soft
counters 1 thorough 6.
0: count as small size (default)
1: count as large size
1
COPY-JOB
Use it to enable/disable copy job reservation with a card reader/coin vendor
in use.
setting
0: enable copy job reservation (default)
1: disable copy job reservation
1
PR-PSESW
Use it to enable/disable the print pause function switch.
setting
0: disable print pause function (default)
1: enable print pause function (display print output stop/resume button on
user screen)
1
IDPRN-SW
Use it to switch over count increment jobs for the group control counter.
0: for PRINT, increment the following: box print, report print, SEND local
print, PDL print (default)
1: for PRINT, increment the following: report print, SEND local print, PDL
print
1
CNT-SW
Use it to switch over display of charge counter default items.
setting
0: default total 1 (101; default)
1: default total 2 (102), copy total 2 (202), total A total 2 (127)
2: default total 1 (101), total small (104), total large (103), scan total 1 (501)
1
TAB-ACC
Use it to enable/disable automatic switchover of cassettes for tab (index)
paper.
setting
0: do not change over between tab sheets (default)
1: change over between tab sheets
1
COPIER > OPTION > BODY
Sub-item
Description
Level
Содержание iR5570 Series
Страница 1: ...Mar 29 2005 Service Manual iR6570 5570 Series ...
Страница 2: ......
Страница 6: ......
Страница 26: ...Contents ...
Страница 27: ...Chapter 1 Introduction ...
Страница 28: ......
Страница 30: ......
Страница 55: ...Chapter 2 Installation ...
Страница 56: ......
Страница 58: ...Contents 2 9 3 Mounting the Cassette Heater 2 34 ...
Страница 98: ......
Страница 99: ...Chapter 3 Basic Operation ...
Страница 100: ......
Страница 102: ......
Страница 110: ......
Страница 111: ...Chapter 4 Main Controller ...
Страница 112: ......
Страница 114: ......
Страница 135: ...Chapter 5 Original Exposure System ...
Страница 136: ......
Страница 181: ...Chapter 6 Laser Exposure ...
Страница 182: ......
Страница 184: ......
Страница 192: ......
Страница 193: ...Chapter 7 Image Formation ...
Страница 194: ......
Страница 198: ......
Страница 259: ...Chapter 8 Pickup Feeding System ...
Страница 260: ......
Страница 299: ...Chapter 8 8 35 F 8 51 PS36 M19 M14 Reversing flapper Outside delivery roller Point of reversal PS37 ...
Страница 349: ...Chapter 8 8 85 F 8 290 1 Feeding roller 2 Separation roller 3 Pressure lever 4 Pressure spring 1 2 A B 3 4 ...
Страница 350: ......
Страница 351: ...Chapter 9 Fixing System ...
Страница 352: ......
Страница 401: ...Chapter 10 External and Controls ...
Страница 402: ......
Страница 406: ......
Страница 448: ......
Страница 449: ...Chapter 11 MEAP ...
Страница 450: ......
Страница 452: ......
Страница 455: ...Chapter 12 Maintenance and Inspection ...
Страница 456: ......
Страница 458: ......
Страница 468: ......
Страница 469: ...Chapter 13 Standards and Adjustments ...
Страница 470: ......
Страница 505: ...Chapter 14 Correcting Faulty Images ...
Страница 506: ......
Страница 508: ......
Страница 537: ...Chapter 15 Self Diagnosis ...
Страница 538: ......
Страница 540: ......
Страница 565: ...Chapter 16 Service Mode ...
Страница 566: ......
Страница 568: ......
Страница 633: ...Chapter 17 Upgrading ...
Страница 634: ......
Страница 636: ......
Страница 641: ...Chapter 17 17 5 F 17 4 HDD Boot ROM Flash ROM System Software ...
Страница 646: ...Chapter 17 17 10 F 17 11 8 Click START F 17 12 ...
Страница 659: ...Chapter 17 17 23 F 17 32 2 Click Start F 17 33 3 When the downloading session has ended click OK ...
Страница 661: ...Chapter 17 17 25 F 17 35 2 Click Start F 17 36 3 When the downloading session has ended click OK ...
Страница 663: ...Chapter 17 17 27 F 17 38 2 Click Start F 17 39 3 When the downloading session has ended click OK ...
Страница 668: ...Chapter 17 17 32 F 17 46 2 Click Start F 17 47 3 When the downloading session has ended click OK ...
Страница 675: ...Chapter 17 17 39 F 17 59 2 Select the data to download F 17 60 3 Click Start ...
Страница 677: ...Chapter 18 Service Tools ...
Страница 678: ......
Страница 679: ...Contents Contents 18 1 Service Tools 18 1 18 1 1 List of Special Tools 18 1 18 1 2 List of Solvents Oils 18 2 ...
Страница 680: ......
Страница 683: ...Mar 29 2005 ...
Страница 684: ......