< Work procedure 1-1>
5 / 7
< Check that the Engagement/Disengagement Cam of the Registration Slave Roller rotates smoothly. (A
loosened screw, a misaligned cam, etc.) [A] >
11) Rotate the Engagement/Disengagement Cam [1] of the Registration Slave Roller to check that the
rotation is smoothly conveyed to the Registration Slave Roller Unit [2] and check the cam [1] for any
abnormality.
12) Check the 3 Fixation Screws [3] securing the Engagement/Disengagement Cam of the Registration
Slave Roller for looseness.
13) If abnormality is found, replace the faulty part.