< Work procedure 1-1>
7 / 7
18) Turn the Registration Unit to allow access to its bottom, and check that the connector [1] of the
Registration Motor is connected properly and that the harness [2] of the Registration Motor is free of
damages.
19) If abnormality is found, replace the faulty part.
< Check the connectors between the Registration Motor (M26) and the
Registration/Duplexing Driver PCB. [D] >
20) Install the removed parts in reverse order, and check the 7 connectors between the Registration Motor
(M26) and the Registration/ Duplexing Driver PCB for disconnection and abnormality.
21) If abnormality is found, replace the faulty part.
22) Install the removed parts in reverse order.