<Work procedure 1-6>
1 / 17
<Remedy>
_Check the Fixation Screws of the Process Unit for any looseness. [A]
_Check the Shaft Support Members for any damage. [B]
_Check the location to install the Laser Scanner Unit for any abnormality. [C]
<Detailed work procedure>
1) Open the Front Left Cover and the Front Right Cover.
Check the Fixation Screws of the Process Unit for any looseness. [A]
2) Remove Process Unit Cover.
3) Check the 4 Fixation Screws [1] of the Process Unit for any looseness.
4) If abnormality is found, replace the faulty part.
5) Install the removed parts in reverse order.