Chapter 7
7-36
4. FAQ
5. Troubleshooting
No.
Question
Answer
Q1
Registration information of the device (E-RDS) is once
deleted from the UGW server, and is re-registered after that.
If a communication test is not
carried out, then device information on UGW becomes
invalid.
When registration of the device (e-RDS) is deleted from the
UGW, the status will be changed to the communication test
not completed because related
information has lost from a database. Therefore, device
information will also become invalid if that condition persists
for seven days without carrying out the communication
test. Hence, to avoid the invalid condition, carry out the
communication test.
Q2
The communication test with the UGW server results NG!
The comunication test might become NG in the following
cases.
- 1. Name resolution was failed due to an incorrect host name
or DNS server has been halted.
- 2. Network cable is blocked off. Network cable is broken.
- 3. Proxy server settings are not correct.
Q3
Could you describe the timing of data transmitting from the
device (e-RDS) to the UGW, and what data size is sent to the
UGW?
The schedule of data transmitting, and the start time are
determined by settings in the UGW side. The timing is once
per 16 hours by default, and counter data size is maximum
1400 bytes.
Q4
Can I turn the device power off during the device (e-RDS)
operation?
While operating the device (e-RDS), the power of the printer
and network equipment such as HUB must be ON. If power
OFF is needed, do not leave it OFF for a long time.
An error such as "Device is busy, try later"could occur if the
power supply of network
equipment is made prolonged OFF.
No.
Condition detected
Action
1
The communication test has failed. Check network conditions such as proxy server settings and so on.
- Check the communication log from COM-LOG. -> Execute "Remedy" in the "Error
message list".
- Check whether RGW-ADDRESS or RGW-PORT settings have changed.
Содержание image Prograf iPF780 Series
Страница 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785...
Страница 9: ...Chapter 1 PRODUCT DESCRIPTION...
Страница 57: ...Chapter 2 TECHNICAL REFERENCE...
Страница 117: ...Chapter 3 INSTALLATION...
Страница 125: ...Chapter 4 DISASSEMBLY REASSEMBLY...
Страница 133: ...Chapter 4 4 7 3 Remove one screw 1 release two hooks 2 and then remove the output guide middle left 3 F 4 11 1 3 2 2...
Страница 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1...
Страница 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1...
Страница 179: ...Chapter 5 MAINTENANCE...
Страница 186: ...Chapter 6 TROUBLESHOOTING...
Страница 212: ...Chapter 7 SERVICE MODE...
Страница 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750...
Страница 275: ...STAND UNIT ST 33 STAND UNIT ST 34 100V Q51 1767 000 230 KOR Q51 1768 000 Q51 2560 000 Q51 2800 000...
Страница 299: ...2 23 FIGURE 09 CUTTER UNIT J12 J7 J11 J31 J34 J33 A A 10 8 1 502 7 5 13 13 9 11 8 501 6 12 2 3 4 14 14 14 15 503...
Страница 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11...
Страница 326: ......