Chapter 7
7-32
2) UGW Address [UGW-ADDRESS] and UGW port [UGW-PORT]
Usually, the default values set in advance are used for the setting value of [UGW-ADDRESS] and [UGW-PORT]. Unless there is a special instruction, the default
value should not be changed. If it should be changed, the communication with UGW may have an error. If [UGW-ADDRESS] and [UGW-PORT] are changed, the
new setting will be enabled after power OFF/ON.
Therefore, usually, the setup is not necessary.
* If you change under a special instruction, perform the following procedure.
(1) Setting address for UGW
- In service mode, referring to the "Service Mode Menu Tree", go to [UGW-ADDRESS] menu using
key and
key.
F-7-40
- Press
key to enter the Setup Mode. (A character indicating the input mode (in the upper right corner of the screen) and the cursor are displayed.)
Enter UGW address (URL).
F-7-41
Display to indicate an input mode
A: Alphabet capital letter
a: Alphabet small letter
1: Numerical character
- The cursor is shown at the first letter.
- Use
and
keys to select characters to enter.
- Press [Back] key to cancel what you entered and go back to the previous screen.
- Press [OK] key to determine what you entered and go back to the previous screen.
(2) Setting up the GW Port Number
- In service mode, referring to the "Service Mode Menu Tree", go to [UGW-PORT] menu using
key and
key.
F-7-42
- Press
key to enter the Setup Mode. (A cursor is displayed.)
Enter a port number.
F-7-43
- Use
and
keys to select characters to enter.
- Press [Back] key to cancel what you entered and go back to the previous screen.
- Press [OK] key to determine what you entered and go back to the previous screen.
* The actual setting value of UGW address [UGW-ADDRESS] and UGW port [UGW-PORT] are categorized as confidential information, so they are not described
in this manual.
3) Communication Test [COM-TEST]
(1) In service mode, referring to the "Service Mode Menu Tree", go to [COM-TEST] menu using
key and
key.
F-7-44
(2) Press [OK] key to start the test. ("=" is displayed at the start of the test.)
F-7-45
(3) During the communication test, "CHECK NOW" is displayed.
F-7-46
U G W
A D D R E S S
E -
R D S
U G W
A D D R E S S
h t
t
p :
/
/
:
a
-
U G W
P O R T
E -
R D S
U G W
P O R T
0 0 0 0 0
-
Y E S
C O M - T E S T
= Y E S
C O M - T E S T
C H E C K
N O W .
.
C O M - T E S T
Содержание image Prograf iPF780 Series
Страница 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785...
Страница 9: ...Chapter 1 PRODUCT DESCRIPTION...
Страница 57: ...Chapter 2 TECHNICAL REFERENCE...
Страница 117: ...Chapter 3 INSTALLATION...
Страница 125: ...Chapter 4 DISASSEMBLY REASSEMBLY...
Страница 133: ...Chapter 4 4 7 3 Remove one screw 1 release two hooks 2 and then remove the output guide middle left 3 F 4 11 1 3 2 2...
Страница 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1...
Страница 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1...
Страница 179: ...Chapter 5 MAINTENANCE...
Страница 186: ...Chapter 6 TROUBLESHOOTING...
Страница 212: ...Chapter 7 SERVICE MODE...
Страница 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750...
Страница 275: ...STAND UNIT ST 33 STAND UNIT ST 34 100V Q51 1767 000 230 KOR Q51 1768 000 Q51 2560 000 Q51 2800 000...
Страница 299: ...2 23 FIGURE 09 CUTTER UNIT J12 J7 J11 J31 J34 J33 A A 10 8 1 502 7 5 13 13 9 11 8 501 6 12 2 3 4 14 14 14 15 503...
Страница 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11...
Страница 326: ......