Chapter 7
7-33
- Once the communication test is started, it cannot be cancelled.(Other operation won't be accepted until the result is obtained.)
(4) If the communication test was successful, "CHECK RSLT:OK" is displayed.
F-7-47
- Press
key to exit this operation mode and go back to the top of [COM-TEST] menu.
(5) If the communication test was failed, "CHECK RSLT:NG" is displayed.
F-7-48
- Press
key to exit this operation mode and go back to the top of [COM-TEST] menu.
- If you cannot obtain the result after 30 seconds from the start of a communication test, the test is considered failed and the same screen will appear.
* When the communication test was successful, it is necessary to take the interval of 5 minutes before performing the next communication test.
4) Communication Log [COM-LOG]
Communication Error Information/Detailed Communication Error Information can be displayed on the screen at the time of a communication error with the Service
Center (including proxy server error). When a communication error occurs, you can refer to this information to study how to deal with the problem.
* For the countermeasure corresponding to each Communication Error Information or Detailed Communication Error Information, see the list of error message in
"4. Troubleshoot".
(1) In service mode, referring to the "Service Mode Menu Tree", go to [COM-LOG] menu using
key and
key.
F-7-49
(2) Press
key, and communication error information is displayed. On the upper line of the LCD, a log number (01-30) and an error code are shown; on the
bottom line, an occurrence date and time of the error is shown.
F-7-50
- COM-LOG information can be saved up to 30 cases.
- Use Right and Left keys to change logs to display.
- Logs are displayed in the sequence of the time of occurrence. (Log number 1 is the latest log.)
- Press
key to exit this operation mode and go back to the top of [COM-LOG] menu.
* If the Communication Error Information is not saved, the screen below will appear.
F-7-51
- Press
key to exit the communication error information screen and go back to the top of [COM-LOG] menu.
(3) Press
key to display the Detailed Communication Error Information (maximum 128 characters).
1st-32nd characters of Detailed Communication Error Information are shown.
F-7-52
33rd-64th characters of Detailed Communication Error Information are shown.
F-7-53
C H E C K
R S L T :
O K
C O M - T E S T
C H E C K
R S L T :
N G
C O M - T E S T
C O M - L O G
E -
R D S
Y Y Y Y /
M M /
D D
H H
: M M
N o
:
0 1
X X X X X X X X H
N O
L O G
C O M - L O G
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
Содержание image Prograf iPF780 Series
Страница 1: ...Mar 27 2014 Service Manual iPF780 760 750 series iPF785...
Страница 9: ...Chapter 1 PRODUCT DESCRIPTION...
Страница 57: ...Chapter 2 TECHNICAL REFERENCE...
Страница 117: ...Chapter 3 INSTALLATION...
Страница 125: ...Chapter 4 DISASSEMBLY REASSEMBLY...
Страница 133: ...Chapter 4 4 7 3 Remove one screw 1 release two hooks 2 and then remove the output guide middle left 3 F 4 11 1 3 2 2...
Страница 175: ...Chapter 4 4 49 2 Shaft Cleaner 1 F 4 97 1 1...
Страница 176: ...Chapter 4 4 50 3 Upper Cover Hinge Catch 1 Roll Cover Slide Guide 2 F 4 98 2 1...
Страница 179: ...Chapter 5 MAINTENANCE...
Страница 186: ...Chapter 6 TROUBLESHOOTING...
Страница 212: ...Chapter 7 SERVICE MODE...
Страница 267: ...Mar 19 2014 PARTS CATALOG iPF786 785 781 780 765 760 755 750...
Страница 275: ...STAND UNIT ST 33 STAND UNIT ST 34 100V Q51 1767 000 230 KOR Q51 1768 000 Q51 2560 000 Q51 2800 000...
Страница 299: ...2 23 FIGURE 09 CUTTER UNIT J12 J7 J11 J31 J34 J33 A A 10 8 1 502 7 5 13 13 9 11 8 501 6 12 2 3 4 14 14 14 15 503...
Страница 301: ...2 25 FIGURE 10 PLATEN GUIDE UNIT 1 3 6 2 8 4 5 10 10 10 9 9 11...
Страница 326: ......