Using Lucina
216
4. Locate and connect the other end of the T-fitting to the NIBP port located
on either side of the mannequin’s torso.
The Battery Compartment and Ports
Non-invasive blood pressure may now be taken using the return-to-flow
technique.
5. Store the modified blood pressure cuff with the mannequin.
Korotkoff Sounds
Korotkoff sounds can be auscultated on either arm.
To auscultate Korotkoff sounds,
1. Wrap the sphygmomanometer cuff around the arm on the same side as
the connected NIBP port.
2. Place the stethoscope just above the brachial pulse.
3. Pump up the blood pressure cuff and let the cuff pressure drop slowly by
opening the valve on the bulb slightly.
4. Monitor the pressure displayed on the cuff gauge.
All five phases should be recognized:
• Phase I - Clear, repetitive, tapping sounds (Systolic)
• Phase II - Longer beats, with some swishing sounds
• Phase III - Crisp, more intense rhythm sounds
• Phase IV - Muffled, less distinct sounds
• Phase V - Sounds disappear completely (Diastolic)
The LEFT
NIBP port