Care and Maintenance
252
12. Disconnect the
UTERUS
pneumatic port from the uterus inflation port
The Uterus Inflation Port and UTERUS Pneumatic Port
13. Disconnect the
BLOOD UTERUS
port from the uterus bleed port.
The Uterus Bleed Port and BLOOD UTERUS Port
14. Ensure all fluid is removed from within the vaginal canal.
15. Wipe the external area particularly the buttocks and under the skin
surrounding the vaginal opening.
The food color will stain more readily if left on for an extended period.
16. Remove the uterus by folding the labia and perineum flaps closed together
and pushing the external genitalia up through the birth canal into the
mannequin’s torso.
The uterus
inflation port
The
UTERUS
pneumatic port
The uterus
bleed port
The
BLOOD
UTERUS
port
Содержание Fidelis Lucina
Страница 1: ...User Guide Maternal Fetal Simulator...
Страница 2: ...2015 CAE Healthcare 905K470052 v2 1...
Страница 28: ...Table Of Contents xxvi This page intentionally blank...
Страница 36: ...Equipment Overview 8 This page intentionally blank...
Страница 190: ...Using M se 162 This page intentionally blank...
Страница 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Страница 266: ...Using Lucina 238 This page intentionally blank...
Страница 298: ...Care and Maintenance 270 This page intentionally blank...
Страница 389: ......