Configuring the Mannequin
19
C
ONFIGURING
T
HE
M
ANNEQUIN
The maternal mannequin must be configured properly in order to run the various SCEs. Prior to
beginning a configuration, users must select a SCE in the Müse software.
NOTE:
To avoid any unexpected behavior, users must click the
Stop
button in the Müse software to end
an SCE is that is currently running prior to selecting a new SCE and configuring the mannequin.
The table below outlines which processes are necessary to properly configuring the mannequin for
each type of SCE.
Process
Prepartum
& Latent
Active
(Non-
Delivery)
Vaginal -
Vertex*
Vaginal -
Breech*
Postpartum -
Boggy/Contracted
Uterus
Installing the Rotation
Ring
No
No
Yes
Yes
No
Removing the Rotation
Ring
Yes
Yes
No
No
Yes
Installing the Support Tub
Yes
Yes
No
No
No
Filling the Blood Tank**
No
No
No
No
Yes
Installing the Blood Tank
No
No
No
No
Yes
Installing the
Boggy/Contracted Uterus
No
No
No
No
Yes
Installing the Prepartum
Birth Canal
Yes
No
No
No
No
Installing the Static Cervix
Yes
No
No
No
No
Installing the Backplate
Yes
No
No
No
Yes
Installing the Retention
Plate
Yes
No
No
No
No
Installing the Uterine
Funnel with Dynamic
Cervix
No
Yes
Yes
Yes
No
Installing the Placenta
No
Yes
Yes
Yes
No
Loading the Fetus
Yes
Yes
Yes
Yes
No
Installing the Prepartum
Abdomen
Yes
Yes
No
No
Yes
Installing the Delivery
Abdomen
No
No
Yes
Yes
No
Содержание Fidelis Lucina
Страница 1: ...User Guide Maternal Fetal Simulator...
Страница 2: ...2015 CAE Healthcare 905K470052 v2 1...
Страница 28: ...Table Of Contents xxvi This page intentionally blank...
Страница 36: ...Equipment Overview 8 This page intentionally blank...
Страница 190: ...Using M se 162 This page intentionally blank...
Страница 226: ...Using the TouchPro CTG Monitor 198 This page intentionally blank...
Страница 266: ...Using Lucina 238 This page intentionally blank...
Страница 298: ...Care and Maintenance 270 This page intentionally blank...
Страница 389: ......