Chapter 5: FDDI MIB

5-18

ATX MIB Reference Guide

fddimibPORTLerCutoff

{fddimibPORTEntry 18}

Integer Read-Write

The link error rate estimate at which a link connection will be broken 
(corresponds to ANSI {fddiPORT 58}).

fddimibPORTLerAlarm

{fddimibPORTEntry 19}

Integer Read-Write

The link error rate estimate at which a link connection will generate an alarm 
(corresponds to ANSI {fddiPORT 59}).

fddimibPORTConnectState

{fddimibPORTEntry 20}

Integer Read-Only

An indication of the connect state of the PORT and is equal to the value of 
Connect_State (corresponds to ANSI {fddiPORT 61}, refer to ANSI 9.4.1).

fddimibPORTPCMState

{fddimibPORTEntry 21}

Integer Read-Only

The state of the Port’s PCM state machine (corresponds to ANSI {fddiPORT 62}, 
refer to ANSI SMT 9.6.2).

fddimibPORTPCWithhold

{fddimibPORTEntry 22}

Integer Read-Only

The value of PC_Withhold (corresponds to ANSI {fddiPORT 63}, refer to ANSI 
SMT 9.4.1).

fddimibPORTLerFlag

{fddimibPORTEntry 23}

Integer Read-Only

The condition becomes active when the value of fddiPORTLerEstimate is less 
than or equal to fddiPORTLerAlarm (corresponds to ANSI {fddiPORT 64}). 
This will be reported with the Status Report Frames (SRF) (refer to ANSI SMT 
7.2.7 and 8.3).

fddimibPORTHardwarePresent

{fddimibPORTEntry 24}

Integer Read-Only

This variable indicates the presence of underlying hardware support for this Port 
object (corresponds to ANSI {fddiPORT 65}). This is always true (1).

Содержание ATX

Страница 1: ...ATX MIB REFERENCE GUIDE 9031872 01 ...

Страница 2: ......

Страница 3: ...BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF CABLETRON SYSTEMS HAS BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Copyright 1996 by Cabletron Systems Inc P O Box 5005 Rochester NH 03866 5005 All Rights Reserve...

Страница 4: ...NING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le présent ...

Страница 5: ...reement shall be interpreted and governed under the laws and in the state and federal courts of New Hampshire You accept the personal jurisdiction and venue of the New Hampshire courts EXCLUSION OF WARRANTY AND DISCLAIMER OF LIABILITY 1 EXCLUSION OF WARRANTY Except as may be specifically provided by Cabletron in writing Cabletron makes no warranty expressed or implied concerning the Program includ...

Страница 6: ...d c in all respects is proprietary data belonging to Cabletron and or its suppliers For Department of Defense units the product is licensed with Restricted Rights as defined in the DoD Supplement to the Federal Acquisition Regulations Section 52 227 7013 c 1 ii and its successors and use duplication disclosure by the Government is subject to restrictions as set forth in subparagraph c 1 ii of the ...

Страница 7: ...m Group 2 1 2 2 Interfaces Group 2 3 2 3 Address Translation Group 2 8 2 4 IP Group 2 9 2 4 1 IP Address Table 2 11 2 4 2 IP Routing Table 2 13 2 4 3 IP Address Translation Table 2 16 2 4 4 IP Additional Objects 2 17 2 5 ICMP Group 2 17 2 6 TCP Group 2 20 2 7 UDP Group 2 21 2 7 1 UDP Listener Table 2 21 2 8 EGP Group 2 22 2 9 OIM Subtree 2 22 2 10 Transmission Group 2 22 2 11 SNMP Group 2 23 CHAPT...

Страница 8: ...roup 5 12 5 4 1 PATH Table 5 12 5 4 2 PATH Config Table 5 14 5 5 PORT Group 5 15 5 5 1 PORT Table 5 15 CHAPTER 6 BRIDGE MIB 6 1 Base Group 6 1 6 2 Spanning Tree Group 6 3 6 3 Source Route Group 6 8 6 4 Transparent Group 6 12 6 5 Static Database Group 6 15 CHAPTER 7 REPEATER MIB 7 1 Basic Package 7 1 7 2 Group Info 7 3 7 3 Port Info 7 5 7 4 Monitor Package 7 7 7 5 Monitor rptr Info 7 7 7 6 Monitor ...

Страница 9: ...ation Status Group 10 15 10 3 3 2 LMA Configuration Group 10 19 10 3 3 3 PPE Configuration Group 10 20 10 3 3 4 Spanning Tree Group 10 26 10 3 3 5 Mesh Group 10 27 10 3 4 Software Distribution Group 10 28 10 3 5 Addresses Configuration Group 10 30 10 3 6 SNMP SMT Support Group 10 40 10 3 7 Cabletron Interfaces Group 10 42 10 3 8 Cabletron FDDI Interfaces Group 10 51 10 3 9 Cabletron UART Interface...

Страница 10: ...88 10 3 20 2 IP Multicast Stat Table 10 89 10 3 21 IP Circuit Table 10 89 10 3 22 sipNetToMedia Table 10 91 10 3 23 Trunking Group 10 91 10 3 24 IP Multicast Route 10 94 10 3 24 1 IPM Route Next Hop Table 10 96 10 3 24 2 IPM Route Interface Table 10 97 10 3 25 IGMP Interface 10 98 10 4 AppleTalk Group 10 100 CHAPTER 11 TRAPS 11 1 Generic Traps 11 1 11 2 Priority 0 Traps 11 2 11 3 Priority 1 Traps ...

Страница 11: ...o perform and describes how to use TFTP to download the ATX system software Chapter 2 TCP IP MIB II describes the standard TCP IP MIB variables Chapter 3 Ethernet MIB describes the standard Ethernet MIB variables Chapter 4 Token Ring MIB describes the Token Ring MIB variables Chapter 5 FDDI MIB describes the FDDI MIB variables Chapter 6 Bridge MIB describes the Bridge MIB variables Chapter 7 Repea...

Страница 12: ...he computer appear in Courier typeface NOTE Note symbol Calls the reader s attention to any item of information that may be of special importance TIP Tip symbol Conveys helpful hints concerning procedures or actions CAUTION Caution symbol Contains information essential to avoid damage to the equipment Warning symbol Warns against an action that could result in equipment damage personal injury or d...

Страница 13: ...n to Management of TCP IP based internets 2nd edition Marshall T Rose Prentice Hall 1994 This manual describes the software interface between the NMS and the ATX This is relevant for a unit running Version 1 0 software The NMS communicates with the ATX software The Network Management or UART port is the interface to the Local Console Manager LCM LCM is a non intelligent terminal interface that can...

Страница 14: ...ia Ethernet 802 3 LAN the datagram must have an Ethernet MAC header with an Ethernet frame type of IP or the datagram must be in 802 3 format with IP encapsulation as defined by RFC 1042 UART out of band management port the datagram must have a PPP header which indicates that the datagram contains an IP packet The unit automatically detects the presence of a PPP connection versus being connected t...

Страница 15: ...ible true 1 or false 2 values note that the ASN 1 BOOLEAN primitive type is not used BridgeID 8 bytes Priority and MAC address used to identify a spanning tree bridge Counter 4 bytes max Unsigned value DisplayString n X1 byte Array of printable ascii characters Gauge 4 bytes Non negative integer Integer 4 bytes max Signed value IpAddress 4 bytes Internet address MacAddress 6 bytes Ethernet address...

Страница 16: ... of significant events the unit uses the Trap PDU The unit implements two non standard features with respect to the SNMP SetRequest The variable bindings within a SetRequest are sometimes processed sequentially rather than simultaneously For example if a SetRequest contains two parameters with an incorrect value specified for the second parameter the unit returns a badValue error to the NMS howeve...

Страница 17: ...hierarchical tree structure Each MIB variable has a numeric value that indicates its place in the hierarchy The structure was originally created and is still maintained by the International Organization for Standardization ISO and the International Telecommunications Union ITU two international standards organizations You can get and set MIB variables by navigating down the tree to a specific MIB ...

Страница 18: ...ld want to get the sysUpTime variable which is the third object in the system group So the get command would look like get 1 3 6 1 2 1 1 3 0 The zero at the end 0 indicates that this is a single instance and that only one value can be returned Whenever you are looking for a variable with only one value you must include the 0 at the end Some variables may have multiple values such as an IP address ...

Страница 19: ...erCurrentCount variable in the Cabletron MIB filter group and add it to the prefix 1 3 6 1 4 1 97 After the prefix add the ATX group ID 2 the filter group ID 9 and the filterCurrentCount ID of 2 As stated above the zero 0 indicates that this variable is a single instance and only one variable can be returned Table 1 2 Branches Under MIB II MIB II Group Number 1 3 6 1 2 1 System 1 Interfaces 2 Addr...

Страница 20: ...urity details 1 8 1 Software Distribution TFTP is used for the distribution of new software The new software will be automatically invoked when a ATX reboots New software is released in two files dnld_hdr dnld_software To distribute the new software to a ATX the TFTP procedure is as follows 1 Start TFTP on the NMS or on any other device which can provide TFTP services Typically TFTP must be starte...

Страница 21: ...y 2 Tell TFTP to retrieve the unit s Configuration file 3 After about ten seconds the TFTP operation will be complete 1 9 ADDITIONAL INTERFACES In addition to SNMP and TFTP the ATX employs the following protocols as part of its software interface with an NMS UDP User Datagram Protocol RFC 768 IP Internet Protocol RFC 791 ARP Ethernet Address Resolution Protocol RFC 826 RARP Reverse Address Resolut...

Страница 22: ...Chapter 1 Introduction 1 12 ATX MIB Reference Guide ...

Страница 23: ...meters are described below sysDescr system 1 DisplayString Read Only A textual description of the unit including the full name and version identification of the software and hardware refer to swDesc and hwManufData The text obeys the format ZAHMHTHOH1H2H3H4 where A a 0 32 character textual description of the current set of software files The current set of files is used whenever the unit boots or ...

Страница 24: ...SI module IFIOM Intelligent FDDI module NONE no module the manufacturing code is all blanks TIOM Token Ring i e 802 5 module QEIOM Quad Ethernet module i e an Ethernet module with 4 ports QTIOM Quad Token Ring module i e a Token Ring module with 4 ports sysObjectID system 2 Object Identifier Read Only The identifier of the variable used to identify the type of entity Cabletron s MIB sysID paramete...

Страница 25: ...lude 2 the unit is a bridge only 4 the unit is an IP router only 6 the unit is both a bridge and an IP router The unit is a bridge and IP router 2 2 INTERFACES GROUP interfaces mib 2 2 The TCP IP Interfaces Group parameters are described below ifNumber interfaces 1 Integer Read Only The number of ports whether alive or dead including the UART as indicated by the Configuration EEPROM The actual por...

Страница 26: ...CEIOM EIOM and QEIOM ports 9 iso88025 tokenRing for TIOM and QTIOM ports 15 fddi for FIOM and IFIOM ports 23 ppp for the UART and HIOM ports ifMtu ifEntry 4 Integer Read Write The size in bytes of the largest network datagram which may be sent or received on the port This does not include the MAC header LLC header and FCS For CSMA CD ports the Ethernet Frame Type is considered part of the MAC head...

Страница 27: ... has its bridging and or routing functions enabled is unknown for the UART the value of ifAdminStatus is always restored to up when the unit reboots down 2 the port is not to be used testing 3 the port is to be put into local loopback this value is not saved if the unit reboots ifOperStatus ifEntry 8 Integer Read Only The current status of the port i e one of the following up 1 the port can send r...

Страница 28: ...rded ifInNUcastPkts ifEntry 12 Counter Read Only The number of multicast packets received by the port regardless of the packet s outcome i e whether the packet was filtered or forwarded ifInDiscards ifEntry 13 Counter Read Only The number of packets received by the port which were filtered by the unit s forward filter decision making ifInErrors ifEntry 14 Counter Read Only The number of packets re...

Страница 29: ...n occurs when too many packets are to be queued for transmission or when packets have been awaiting transmission for too long a time period ifOutErrors ifEntry 20 Counter Read Only The number of packets that were to be transmitted out the port but incurred transmission hardware errors ifOutQLen ifEntry 21 Gauge Read Write The maximum length ever obtained by the port s outbound packet queue in pack...

Страница 30: ...Group will be deleted from TCP IP MIB III since there will be separate address translation tables for every type of network protocol indeed TCP IP MIB II already defines the IP Address Translation Table The TCP IP Address Translation Group parameters are described below atTable at 1 Not Accessible atEntry atTable 1 Not Accessible atIfIndex atEntry 1 Integer Read Write All GetResponse PDUs indicate...

Страница 31: ...header when this unit creates IP datagrams ipInReceives ip 3 Counter Read Only The total number of IP packets received from all ports including the UART ipInHdrErrors ip 4 Counter Read Only The number of packets received that were discarded due to errors in the IP header ipInAddrErrors ip 5 Counter Read Only The number of packets received that were discarded due to an invalid or nonroutable destin...

Страница 32: ... Read Only The total number of output packets which were discarded due to lack of resources for example This counter includes packets which would be included in ipForwDatagrams if any such packets were discarded ipOutNoRoutes ip 12 Counter Read Only The number of packets which were discarded because no route could be found to transmit them to their destination This counter includes any packets cou...

Страница 33: ...ounter Read Only The number of IP datagrams that have been discarded because they needed to be fragmented but could not be e g because their Don t Fragment flag was set ipFragCreates ip 19 Counter Read Only The number of IP datagram fragments that have been generated by this unit 2 4 1 IP Address Table The TCP IP IP Address Table contains the IP addressing information for each port The parameters ...

Страница 34: ...3 The network subnet mask associated with the IP address For SetRequests a mask of zero may be specified in which case the unit will create the correct network mask for a non subnetted network For GetRequests the unit will always convert a value of zero into the correct network mask ipAdEntBcastAddr ipAddrEntry 4 Integer Read Only The value for the least significant bit for broadcasts i e the cons...

Страница 35: ...e standard network class mask based on the row s instance identifier except 255 255 255 255 is used if the row s instance identifier contains a non zero host portion Parameters include the following variables ipRouteTable ip 21 Not Accessible A list of routing entries one per route An entry is keyed by an IP address ipRouteDest defined below If there are multiple entries for the same IP address th...

Страница 36: ...be greater than zero ipRouteMetric3 ipRouteEntry 5 Integer Read Write An alternative routing metric for this route ipRouteMetric4 ipRouteEntry 6 Integer Read Write An alternative routing metric for this route ipRouteNextHop ipRouteEntry 7 IP Address Read Write The IP address of the route s next hop ipRouteType ipRouteEntry 8 Integer Read Write The type of the route one of the following other 1 non...

Страница 37: ...he remaining values are all gateway routing protocols egp 5 ggp 6 hello 7 rip 8 is is 9 es is 10 ciscoIgrp 11 bbnSpfIgp 12 ospf 13 bgp 14 ipRouteAge ipRouteEntry 10 Integer Read Write The number of seconds since the route was last updated or deemed to be correct ipRouteMask ipRouteEntry 11 IP Address Read Write The mask to be ANDed with the destination IP address before being compared to the value...

Страница 38: ...on that a dynamic entry should not be modified except to be made invalid any other modifications will cause a static entry to be created When adding a row the following defaults are used ipNetToMediaIfIndex is obtained from the row s instance identifier ipNetToMediaPhysAddress defaults to 0 ipNetToMediaNetAddress is obtained from the row s instance identifier ipNetToMediaType defaults to static Pa...

Страница 39: ...ysAddress ipNetToMediaType ipNetToMediaEntry 4 Integer Read Write The type of address mapping one of the following other 1 none of the below invalid 2 the entry should be considered to be non existent dynamic 3 the mapping was dynamically learned static 4 the mapping was statically configured 2 4 4 IP Additional Objects The TCP IP additional IP objects are described below ipRoutingDiscards ip 23 C...

Страница 40: ...sages received icmpInParmProbs icmp 5 Counter Read Only The number of ICMP Parameter Problem messages received icmpInSrcQuenchs icmp 6 Counter Read Only The number of ICMP Source Quench messages received icmpInRedirects icmp 7 Counter Read Only The number of ICMP Redirect messages received icmpInEchos icmp 8 Counter Read Only The number of ICMP Echo request messages received icmpInEchoReps icmp 9 ...

Страница 41: ...nt by this unit This includes all messages counted by icmpOutErrors icmpOutErrors icmp 15 Counter Read Only The number of ICMP messages which this unit did not send due to problems discovered entirely within the ICMP subsystem such as lack of buffers icmpOutDestUnreachs icmp 16 Counter Read Only The number of ICMP Destination Unreachable messages sent icmpOutTImeExcds icmp 17 Counter Read Only The...

Страница 42: ...y messages sent icmpOutTimestamps icmp 23 Counter Read Only The number of ICMP Timestamp request messages sent icmpOutTimestampReps icmp 24 Counter Read Only The number of ICMP Timestamp Reply messages sent icmpOutAddrMasks icmp 25 Counter Read Only The number of ICMP Address Mask Request messages sent icmpOutAddrMaskReps icmp 26 Counter Read Only The number of ICMP Address Mask Reply messages sen...

Страница 43: ...of an application at the destination port udpOutDatagrams udp 4 Counter Read Only The total number of UDP datagrams sent from this unit 2 7 1 UDP Listener Table The TCP IP UDP Listener Table parameters are described below udpTable udp 5 Not Accessible A table containing UDP listener information The table has entries for the following UDP port numbers port 69 default TFTP port number port 161 SNMP ...

Страница 44: ...UDP port number 162 is not supported by the unit 2 8 EGP GROUP egp mib 2 8 The EGP Group is not supported since the unit does not support EGP 2 9 OIM SUBTREE cmot mib 2 9 The OSI Subtree as defined in OSI internet management Management Information Base RFC 1214 L LaBarre editor dated April 1991 is not supported 2 10 TRANSMISSION GROUP transmission mib 2 10 The supported TCP IP Transmission Group p...

Страница 45: ... an unsupported SNMP version snmpInBadCommunityNames snmp 4 Counter Read Only The number of SNMP PDUs received by the unit which had an unrecognized SNMP community name snmpInBadCommunityUses snmp 5 Counter Read Only The number of SNMP PDUs received by the unit which had an authentication failure snmpInASNParseErrs snmp 6 Counter Read Only The number of SNMP PDUs received by the unit which had an ...

Страница 46: ...unit ignores all SNMP response PDUs snmpInGenErrs snmp 12 Counter Read Only Always zero since the unit ignores all SNMP response PDUs snmpInTotalReqVars snmp 13 Counter Read Only The total number of MIB objects which have been successfully retrieved by the unit as a result of SNMP GetRequest or GetNext PDUs snmpInTotalSetVars snmp 14 Counter Read Only The total number of MIB objects which have bee...

Страница 47: ...snmp 19 Counter Read Only Always zero since the unit ignores all SNMP Trap PDUs snmpOutTooBigs snmp 20 Counter Read Only The total number of SNMP PDUs created by the unit with a value of tooBig in the PDU s ErrorStatus snmpOutNoSuchNames snmp 21 Counter Read Only The total number of SNMP PDUs created by the unit with a value of noSuchName in the PDU s ErrorStatus snmpOutBadValues snmp 22 Counter R...

Страница 48: ...t never creates any SNMP request PDUs snmpOutSetRequests snmp 27 Counter Read Only Always zero since the unit never creates any SNMP request PDUs snmpOutGetResponses snmp 28 Counter Read Only The total number of SNMP GetResponse PDUs created by the unit snmpOutTraps snmp 29 Counter Read Only The total number of SNMP Trap PDUs created by the unit snmpEnableAuthenTraps snmp 30 Integer Read Write Whe...

Страница 49: ...sion 7 dot3Table dot3 1 Not Accessible A list of interface entries one per Ethernet port The entry instances correspond to the unit s port numbers For example if the unit s 2nd port is Ethernet then both ifindex 2 and dot3Index 2 contain the value 2 If the unit s 2nd port is not Ethernet then referencing dot3Index 2 should return noSuchName dot3Entry dot3Table 1 Not Accessible A set of operational...

Страница 50: ...Integer Read Write Treated identically to dot3InitializeMAC Values include enabled 1 disabled 2 dot3MulticastReceiveStatus dot3Entry 4 Integer Read Write Whether the port is able to receive multicasts This is always enabled when the port is enabled and always disabled when the port is disabled Values include enabled 1 disabled 2 dot3TxEnabled dot3Entry 5 Integer Read Write Whether the port is able...

Страница 51: ...try 1 Integer Read Only The unit s Ethernet port number dot3StatsAlignmentErrors dot3StatsEntry 2 Counter Read Only Number of received packets with frame alignment errors since the port was last enabled dot3StatsFCSErrors dot3StatsEntry 3 Counter Read Only Number of received packets with FCS errors and without frame alignment errors since the port was last enabled dot3StatsSingleCollisionFrames do...

Страница 52: ...atsLateCollisions dot3StatsEntry 8 Counter Read Only The number of times that a late collision was detected Zero is always returned dot3StatsExcessiveCollisions dot3StatsEntry 9 Counter Read Only The number of times a frame transmission attempt experienced excessive collisions since the port was last enabled dot3StatsInternalMACTransmitErrors dot3StatsEntry 10 Counter Read Only The number of times...

Страница 53: ...th an LLC data size that is too large not including frames that have an Ethernet frame type field Zero is always returned dot3StatsInternalMACReceiveErrors dot3StatsEntry 16 Counter Read Only The number of times a frame reception failed due to an error condition not already accounted for since the port was last enabled 3 3 ETHERNET LIKE COLLISION STATISTICS GROUP dot3CollTable dot3 5 This group is...

Страница 54: ...Chapter 3 Ethernet MIB 3 6 ATX MIB Reference Guide 3 6 ETHERNET LIKE CHIPSETS GROUP dot3ChipSets dot3 8 There are no MIB variables in this group ...

Страница 55: ...Accessible This table contains Token Ring interface parameters and state variables on entry per 802 5 interface The entry instances correspond to the unit s port numbers For example if the unit s 2nd port is 802 5 then both ifIndex2 and dot5IfIndex 2 contain the value 2 If the unit s 2nd port is not 802 5 then referencing dot5IfIndex 2 should return noSuchName dot5Entry dot5Table 1 Not Accessible ...

Страница 56: ...op 1 has no effect When read this object always has a value of no op 1 dot5RingStatus dot5Entry 3 Integer Read Only The current interface status which can be used to diagnose fluctuating problems that can occur on token rings after a station has successfully been added to the ring Before an open is completed this object has the value for the no status condition The dot5RingState and dot5RingOpenSt...

Страница 57: ...st recent attempt to enter the ring Values include noOpen 1 no open attempted badParam 2 lobeFailed 3 dot5RingSpeed dot5 Entry 6 Integer Read Write The ring s bandwidth dot5UpStream dot5Entry 7 MacAddress Read Only The Mac address of the up stream neighbor station in the ring dot5ActMonParticipate dot5Entry 8 Integer Read Write If this object has a value of true 1 then this interface will particip...

Страница 58: ...ry dot5StatsTable 1 Not Accessible An entry contains the 802 5 statistics for a particular interface dot5StatsIfIndex dot5StatsEntry 1 Integer Read Only The value of this object identifies the 802 5 interface for which this entry contains management information The value of this object for a particular interface has the same value as the ifIndex object for the same interface dot5StatsLineErrors do...

Страница 59: ... This counter is incremented when a station is transmitting and its TRR timer expires This condition denotes a condition where a transmitting station in strip mode does not receive the trailer of the frame before the TRR timer goes off dot5StatsReceiveCongestions dot5StatsEntry 8 Counter Read Only This counter is incremented when a station recognizes a frame addressed to its specific address but h...

Страница 60: ...om the ring dot5StatsTransmitBeacons dot5StatsEntry 14 Counter Read Only The number of times this interface has transmitted a beacon frame dot5StatsRecoverys dot5StatsEntry 15 Counter Read Only The number of Claim Token MAC frames received or transmitted after the interface has received a Ring Purge MAC frame This counter signifies the number of times the ring has been purged and is being recovere...

Страница 61: ...nter Read Only The number of times the interface has detected that the frequency of the incoming signal differs from the expected frequency by more than that specified by the IEEE 802 5 standard 4 1 3 Token Ring Timer Table dot5TimerTable dot5 3 This entire group is just minimally supported i e the unit returns a GetResponse with a noSuchName ErrorStatus 4 1 4 Token Ring Tests dot5Tests dot5 4 The...

Страница 62: ...Chapter 4 Token Ring MIB 4 8 ATX MIB Reference Guide ...

Страница 63: ...by an asterisk other parameters have been changed from Read Write to Read Only indicated by a number sign The access type of all other parameters is as indicated in the standard MIB The MIB branch for reaching the SMT group is 1 3 6 1 2 1 10 5 1 SMT GROUP fddi transmission 15 This group supports SMT version 7 3 Version 6 2 was supported in release 2 3 of ATX system software however it has been dep...

Страница 64: ... to the unit s first FDDI port which cannot be port number 1 since port number 1 is the UART fddimibSMTStationID fddimibSMTEntry 2 Octet String Read Write Used to uniquely identify an FDDI station corresponds to ANSI fddiSMT 11 Setting the lower six bytes to zero will cause the unit to automatically use the port s MAC address in the lower six bytes fddimibSMTOpVersionID fddimibSMTEntry 3 Integer R...

Страница 65: ...TEntry 8 Integer Read Only The number of MACs in this station or concentrator corresponds to ANSI fddiSMT 21 fddimibSMTNonMasterCts fddimibSMTEntry 9 Integer Read Only The value of this variable is the number of A B and S ports in this station or concentrator corresponds to ANSI fddiSMT 22 fddimibSMTMasterCts fddimibSMTEntry 10 Integer Read Only The number of M Ports in a node If the node is not a...

Страница 66: ...x00000040 CONN_REJECT_BM 0x00000080 CONN_REJECT_SA 0x00000100 CONN_REJECT_SB 0x00000200 CONN_REJECT_SS 0x00000400 CONN_REJECT_SM 0x00000800 CONN_REJECT_MA 0x00001000 CONN_REJECT_MB 0x00002000 CONN_REJECT_MS 0x00004000 CONN_REJECT_MM 0x00008000 fddimibSMTTNotify fddimibSMTEntry 15 Integer Read Write The timer expressed in seconds used in the Neighbor Notification protocol corresponds to ANSI fddiSM...

Страница 67: ...ntry 20 Integer Read Only The attachment configuration for the station or concentrator corresponds to ANSI fddiSMT 42 refer to ANSI SMT 9 7 2 2 fddimibSMTRemoteDisconnectFlag fddimibSMTEntry 21 Integer Read Only Whether the port has been intentionally disconnected corresponds to ANSI fddiSMT 44 The NMS may cause an intentional disconnect or the unit may be configured to not use the FDDI port fddim...

Страница 68: ...o be performed corresponds to ANSI fddiSMT 60 Only connect 2 and disconnect 3 are supported The value of fddimibSMTStationAction is not saved in the event that the unit reboots 5 2 MAC GROUP fddimibMAC fddimib 2 FddimibMACNumber fddimibMAC 1 Integer Read Only The number of FDDI port configured in Configuration EEPROM Note that fddimibMACNumber and fddimibSMTNumber always have identical values in t...

Страница 69: ... ifEntry For example if the unit has a single FDDI port which is the unit s port n then fddimibMACIfIndex 1 contains n and the nth instance of ifEntry contains additional information concerning the port fddimibMACFrameStatusFunctions fddimibMACEntry 4 Integer Read Only Indicates the MAC s optional Frame Status processing functions corresponds to ANSI fddiMAC 11 This is always 6 fs setting and fs c...

Страница 70: ...nd is only modified as specified by the Neighbor Information Frame protocol refer to ANSI SMT 7 2 1 and 8 2 fddimibMACOldUpstreamNbr fddimibMACEntry 11 Octet String Read Only The previous value of the MAC s upstream neighbor s long individual MAC address corresponds to ANSI fddiMAC 26 It has an initial value of the SMT Unknown MAC Address and is only modified as specified by the Neighbor Informati...

Страница 71: ...SMTAddress fddimibMACEntry 16 Octet String Read Only The 48 bit individual address of the MAC used for SMT frames corresponds to ANSI fddiMAC 41 fddimibMACTReq fddimibMACEntry 17 FddiTime Read Only This variable is the T_Req_value passed to the MAC corresponds to ANSI fddiMAC 51 fddimibMACTNeg fddimibMACEntry 18 FddiTime Read Only The T_Neg value determined by this MAC corresponds to ANSI fddiMAC ...

Страница 72: ...ld as closely as possible match the number of frames transmitted by this MAC corresponds to ANSI fddiMAC 73 refer to ANSI MAC 7 5 Note that this count does not include MAC frames Any attempt to write this parameter will cause the MAC s Frame_Ct Copied_Ct Transmit_Ct Error_Ct and Lost_CT to be zeroed fddimibMACErrorCts fddimibMACEntry 24 Counter Read Write A count of the number of frames that were ...

Страница 73: ...bMACEntry 29 Integer Read Only The RMT flag Duplicate Address Flag DA_Flag corresponds to ANSI fddiMAC 112 refer to ANSI MAC 10 2 1 2 fddimibMACUnaDaFlag fddimibMACEntry 30 Integer Read Only A flag UNDA_Flag corresponds to ANSI fddiMAC 113 refer to ANSI MAC 8 2 2 1 set when the upstream neighbor reports a duplicate address condition Cleared when the condition clears fddimibMACFrameErrorFlag fddimi...

Страница 74: ...ib 3 This is the Enhanced MAC Counters group Implementation of this Group is optional but systems claiming support must implement all variables in this group This device does not support this Group 5 4 PATH GROUP fddimibPATH fddimib 4 fddimibPATHNumber fddimibPATH 1 Integer Read Only The total number of PATHs possible across all FDDI ports on this unit 5 4 1 PATH Table fddimibPATHTable fddimibPATH...

Страница 75: ...value of fddiMACTvxValue is managed by setting this variable Possible values range from 40960 40 96 microseconds to 5202000 5 2 milliseconds fddimibPATHTMaxLowerBound fddimibPATHEntry 4 FddiTime Read Write Specifies the minimum time value of fddiMACTMax that shall be used by the MAC that is configured in this path corresponds to ANSI fddiPATH 22 The operational value of fddiMACTMax is managed by s...

Страница 76: ...teger Read Only The value of the PATH resource index associated with this configuration entry fddimibPATHConfigTokenOrder fddimibPATHConfigEntry 3 Integer Read Only An object associated with Token order for this entry Thus if the token passes resources a b c and d in that order then the value of this object for these resources would be 1 2 3 and 4 respectively fddimibPATHConfigResourceType fddimib...

Страница 77: ...ORTEntry fddimibPORTTable 1 Not Accessible A set of operational attributes for a PHY entry The individual components are described below fddimibPORTSMTIndex fddimibPORTEntry 1 Integer Read Only The value of the SMT index associated with this PORT fddimibPORTIndex fddimibPORTEntry 2 Integer Read Only A unique value for each PORT within a given SMT which is the same as the corresponding resource ind...

Страница 78: ...y 7 Integer Read Only Indicates the Path s into which this PORT is currently inserted corresponds to ANSI fddiPORT 16 fddimibPORTRequestedPaths fddimibPORTEntry 8 Octet String Read Only This variable is a list of permitted Paths where each list element defines the Port s permitted Paths corresponds to ANSI fddiPORT 17 The first octet corresponds to none the second octet to tree and the third octet...

Страница 79: ...T 9 4 3 3 fddimibPORTLCTFailCts fddimibPORTEntry 14 Counter Read Only The count of the consecutive times the link confidence test LCT has failed during connection management corresponds to ANSI fddiPORT 42 refer to ANSI 9 4 1 fddimibPORTLerEstimate fddimibPORTEntry 15 Integer Read Only A long term average link error rate corresponds to ANSI fddiPORT 51 refer to ANSI SMT9 4 7 5 fddimibPORTLemReject...

Страница 80: ...dimibPORTPCMState fddimibPORTEntry 21 Integer Read Only The state of the Port s PCM state machine corresponds to ANSI fddiPORT 62 refer to ANSI SMT 9 6 2 fddimibPORTPCWithhold fddimibPORTEntry 22 Integer Read Only The value of PC_Withhold corresponds to ANSI fddiPORT 63 refer to ANSI SMT 9 4 1 fddimibPORTLerFlag fddimibPORTEntry 23 Integer Read Only The condition becomes active when the value of f...

Страница 81: ...t action to be performed corresponds to ANSI fddiPORT 70 The unit always tries to start the port if the relevant hardware passes diagnostics and if the port is configured to be used Attempts to write to this field with values that are not consistent with the above will result in badValue being returned ...

Страница 82: ...Chapter 5 FDDI MIB 5 20 ATX MIB Reference Guide ...

Страница 83: ...ng Read Write The MAC address used by this bridge when it must be referred to in a unique fashion It is recommended that this be the numerically smallest MAC address of all ports that belong to this bridge However it is only required to be unique When concatenated with dot1dStpPriority a unique BridgeIdentifier is formed which is used in the Spanning Tree Protocol The unit s dot1dBaseBridgeAddress...

Страница 84: ...t of the bridge dot1dBasePort dot1dBasePortEntry 1 Integer Read Only The port number of the port for which this entry contains bridge management information Identical to dot1dBasePortIfIndex dot1dBasePortIfIndex dot1dBasePortEntry 2 Integer Read Only The value of the instance of the ifIndex object for the interface corresponding to this port dot1dBasePortCircuit dot1dBasePortEntry 3 Object Identif...

Страница 85: ...of what version of the Spanning Tree Protocol is being run The value decLb100 2 indicates the DEC LANbridge 100 Spanning Tree protocol IEEE 802 1d implementations will return ieee8021d 3 If future versions of the IEEE Spanning Tree Protocol are released that are incompatible with the current version a new value will be defined Always iee8021d 3 dot1dStpPriority dot1dStp 2 Integer Read Write The va...

Страница 86: ...tpRootPort dot1dStp 7 Integer Read Only The port number of the port which offers the lowest cost path from this bridge to the root bridge Port number of this bridge s current spanning tree root port or 0 if this bridge is the current spanning tree root bridge dot1dStpMaxAge dot1dStp 8 Integer Read Only The maximum age of Spanning Tree Protocol information learned from the network on any port befor...

Страница 87: ... others would start using if when this bridge were to become the root dot1dStpBridgeMaxAge dot1dStp 12 TimeTicks Read Write The value that all bridges use for MaxAge when this bridge is acting as the root Note that 802 1d D9 specifies that the range for this parameter is related to the value of dot1dStpBridgeHelloTime The granularity of this timer is specified by 802 1d D9 to be 1 second An agent ...

Страница 88: ...Table dot1dStp 15 Not Accessible A table that contains port specific information for the Spanning Tree Protocol All of the unit s ports are included in this table regardless of whether the Spanning Tree Protocol is currently enabled for the ports dot1dStpPortEntry dot1dStpPortTable 1 Not Accessible A list of information maintained by every port about the Spanning Tree Protocol state for that port ...

Страница 89: ...ite The enabled disabled status of the port The unit does not change the parameter s value when processing a SetRequest refer to the sprotoBridge parameter in Cabletron s enterprise specific MIB for the SetRequest capabilities dot1dStpPortPathCost dot1dStpPortEntry 5 Integer Read Write The contribution of this port to the path cost of paths towards the spanning tree root which include this port An...

Страница 90: ... this port considers to be the Designated Bridge for this port s segment dot1dStpPortDesignatedPort dot1dStpPortEntry 9 Octet String Read Only The Port Identifier of the port on the Designated Bridge for this port s segment dot1dStpPortForwardTransitions dot1dStpPortEntry 10 Counter Read Only The number of times this port has transitioned from the Learning state to the Forwarding state 6 3 SOURCE ...

Страница 91: ..._ 2 dot1dSrPortLocalSegment dot1dSrPortEntry 3 Integer Read Write The segment number that uniquely identifies the segment to which this port is connected Current source routing protocols limit this value to the range 0 through 4095 A value of 65535 signifies that no segment number is assigned to this port dot1dSrPortBridgeNum dot1dSrPortEntry 4 Integer Read Write A bridge number uniquely identifie...

Страница 92: ...It is recommended that a reasonable legal value be chosen dot1dSrPortSTESpanMode dot1dSrPortEntry 7 Integer Read Write Determines how this port behaves when presented with a Spanning Tree Explorer frame The value disabled 2 indicates that the port will not accept or send Spanning Tree Explorer packets any STE packets received will be silently discarded The value forced 3 indicates the port will al...

Страница 93: ...s port from its segment dot1dSrPortSteOutFrames dot1dSrPortEntry 13 Counter Read Only The number of spanning tree explorer frames that have been transmitted by this port on its segment dot1dSrPortSegmentMismatchDiscards dot1dSrPortEntry 14 Counter Read Only The number of explorer frames that have been discarded by this port because the routing descriptor field contained an invalid adjacent segment...

Страница 94: ... dot1dTpAgingTime dot1dTp 2 Integer Read Write The timeout period in seconds for aging out dynamically learned forwarding information dot1dTpFdbTable dot1dTp 3 Not Accessible A table that contains information about unicast entries for which the bridge has forwarding and or filtering information This information is used by the transparent bridging function in determining how to propagate a received...

Страница 95: ...addressed to the value of the corresponding instance of dot1dTpFdbAddress are being forwarded invalid 2 this entry is not longer valid e g it was learned but has since aged out but has not yet been flushed from the table learned 3 the value of the corresponding instance of dot1dTpFdbPort was learned and is being used self 4 the value of the corresponding instance of dot1dTpFdbAddress represents on...

Страница 96: ...its segment Note that a frame received on the interface corresponding to this port is only counted by this object if and only if it is for a protocol being processed by the local bridging function dot1dTpPortOutFrames dot1dTpPortEntry 4 Counter Read Only The number of frames that have been transmitted by this port to its segment Note that a frame transmitted on the interface corresponding to this ...

Страница 97: ...s that have no entries defined A superset of this table s information can be found by using Cabletron s enterprise specific Addresses Configuration Group dot1dStaticEntry dot1dStaticTable 1 Not Accessible Filtering information configured into the bridge by local or network management specifying the set of ports to which frames received from a specific port and containing a specific destination add...

Страница 98: ...ally as part of a full matrix of entry ports and allowed to go exit ports The value of dot1dStaticAllowedToGoTo corresponds to one row of the matrix Creation of the first entry causes the entire matrix to be created Rows are created for all other entries with dot1dStaticAllowedToGoTo values of zero Note that the creation of a static entry for an entry port causes the MAC address to be treated acco...

Страница 99: ...asicPackage snmpDot3RptrMgt 1 rptrRptrInfo rptrBasicPackage 1 rptrGroupCapacity rptrRptrInfo 1 Integer Read Only The rptrGroupCapacity is the number of groups that can be contained within the repeater Within each managed repeater the groups are uniquely numbered in the range from 1 to rptrGroupCapacity Some groups may not be present in the repeater in which case the actual number of groups present...

Страница 100: ... for problem resolution The unit always returns a zero length string rptrReset rptrRptrInfo 4 Integer Read Write Setting this object to reset 2 causes a transition to the START state Setting this object to noReset 1 has no effect The agent will always return the value noReset 1 when this object is read This action does not reset the management counters defined in this document nor does it affect t...

Страница 101: ...fect The agent will always return the value noSelfTest 1 when this object is read This test does nothing rptrTotalPartitionedPorts rptrRptrInfo 6 Gauge Read Only Returns the total number of ports in the repeater whose current state meets all three of the following criteria rptrPortOperStatus does not have the value notPresent 3 rptrPortAdminStatus is enabled 1 and rptrPortAutoPartitionState is aut...

Страница 102: ...nd unambiguous means for determining what kind of group is being managed For example this object could take the value 1 3 6 1 4 1 4242 1 2 14 if vendor Doe Inc was assigned the subtree 1 3 6 1 4 1 4242 and had assigned the identifier 1 3 6 1 4 1 4242 1 2 14 to its Mary Doe 6 Port FOIRL Plug in Module This value is sysID a b c where a is the manufacturing class number of the CEIOM b is the CEIOM s ...

Страница 103: ...ity Note In practice this will generally be the number of ports on a module card or board and the port numbers will correspond to numbers marked on the physical embodiment 7 3 PORT INFO rptrPortInfo rptrBasicPackage 3 rptrPortTable rptrPortInfo 1 Not Accessible Table of descriptive and status information about the ports rptrPortEntry rptrPortTable 1 Not Accessible An entry in the table containing ...

Страница 104: ...e becomes notAutoPartitioned 1 regardless of its pre disabling state rptrPortAutoPartitionState rptrPortEntry 4 Integer Read Only The autoPartitionState flag indicates whether the port is currently partitioned by the repeater s auto partition protection The conditions that cause port partitioning are specified in partition state machine in section 9 IEEE 802 3 std They are not differentiated here ...

Страница 105: ... and error statistics for the groups rptrMonitorGroupEntry rptrMonitorGroupTable 1 Not Accessible An entry in the table containing total performance and error statistics for a single group Regular retrieval of the information in this table provides a means of tracking the performance and health of the networked devices attached to this group s ports The counters in this table are redundant in the ...

Страница 106: ...s statistic provides an indicator of the total data transferred The approximate minimum time for rollover of this counter is 58 minutes rptrMonitorGroupTotalErrors rptrMonitorGroupEntry 4 Counter Read Only The total number of errors which have occurred on all of the ports in this group This counter is the summation of the values of the rptrMonitorPortTotalErrors counters for all of the ports in th...

Страница 107: ...ximate minimum time for rollover of this counter is 80 hours rptrMonitorPortReadableOctets rptrMonitorPortEntry 4 Counter Read Only This object is the number of octets contained in valid frames length that have been received on this port This counter is incremented by OctetCount for each frame received on this port which has been determined to be a readable frame This statistic provides an indicat...

Страница 108: ...er nor the rptrMonitorPortAlignmentErrors Counter shall be incremented for the same frame The approximate minimum time for rollover of this counter is 61 days rptrMonitorPortShortEvents rptrMonitorPortEntry 8 Counter Read Only This counter is incremented by one for each CarrierEvent on this port with ActivityDuration less than ShortEventMaxTime ShortEventMaxTime is greater than 74 bit times and le...

Страница 109: ...within the state machine Runts usually indicate collision fragments a normal network event In certain situations associated with large diameter networks a percentage of runts may exceed ValidPacketMinTime The approximate minimum time for rollover of this counter is 16 hours rptrMonitorPortCollisions rptrMonitorPortEntry 10 Counter Read Only This counter is incremented by one for any CarrierEvent o...

Страница 110: ...exact degree of mismatch is vendor specific and is to be defined by the vendor for conformance testing When this event occurs other counters whose increment conditions were satisfied may or may not also be incremented at the implementor s discretion Whether or not the repeater was able to maintain data integrity is beyond the scope of this standard This is polled from the RIC event record register...

Страница 111: ... summation of information already available through other objects However it is included specifically because the regular retrieval of this object as a means of tracking the health of a port provides a considerable optimization of network management traffic over the otherwise necessary retrieval of the summed counters 7 8 ADDRESS TRACKING PACKAGE snmpDot3RptrMgt 3 7 9 ADDRESS TRACKING RPTR INFO rp...

Страница 112: ...es the port within the group for which this entry contains information rptrAddrTrackLastSourceAddress rptrAddrTrackEntry 3 Octet String Read Only This object is the SourceAddress of the last readable frame i e counted by rptrMonitorPortReadableFrames received by this port rptrAddrTrackSourceAddrChanges rptrAddrTrackEntry 4 Counter Read Only This counter is incremented by one for each time that the...

Страница 113: ...eger Read only The value of ifIndex that identifies the lower level interface over which this PPP Link is operating This interface would usually be an HDLC or RS 232 type of interface If there is no lower layer interface element or there is no ifEntry for the element or the element can not be identified then the value of this object is 0 For example suppose that PPP is operating over a serial port...

Страница 114: ...ngth exceeded the MRU This counter is a component of the ifInErrors variable that is associated with the interface that represents this PPP Link pppLinkStatusBadFCSs pppLinkStatusEntry 5 Counter Read only The number of received packets that have been discarded due to having an incorrect FCS This counter is a component of the ifInErrors variable that is associated with the interface that represents...

Страница 115: ...he ACC Map used by the remote PPP entity when transmitting packets to the local PPP entity The value of this object is meaningful only when the link has reached the open state ifOperStatus is up pppLinkStatusLocalToRemoteProtocolCompression pppLinkStatusEntry 10 Integer Read only Indicates whether the local PPP entity will use protocol compression when transmitting packets to the remote PPP entity...

Страница 116: ... compression disabled 2 no support for ACC map compression pppLinkStatusTransmitFcsSize pppLinkStatusEntry 14 Integer Read only The size of the Frame Check Sequence FCS in bits that the local node will generate when sending packets to the remote node The value of this object is meaningful only when the link has reached the open state ifOperStatus is up 16 bit FCS is the only FCS supported pppLinkS...

Страница 117: ...C Map that is required in order to ensure that the local modem will successfully receive all characters The actual ACC map used on the receive side of the link will be a combination of the local node s pppLinkConfigReceiveACCMap and the remote node s pppLinkConfigTransmitACCMap Changes to this object take effect when the link is next restarted The only value supported is 0 no ACC map pppLinkConfig...

Страница 118: ... with any FCS size negotiations initiated by the remote node per the PPP specification Changing this object will have effect when the link is next restarted Currently only 16 bit FCS is supported pppLqrTable pppLqr 1 Not Accessible Table containing the LQR parameters and statistics for the local PPP entity The ATX always has an empty table pppLqrEntry pppLqrTable 1 Not Accessible LQR information f...

Страница 119: ...s of a second that is in effect for the remote PPP entity pppLqrOutLQRs pppLqrEntry 5 Counter Read only The value of the OutLQRs counter on the local node for the link identified by ifIndex pppLqrInLQRs pppLqrEntry 6 Counter Read only The value of the InLQRs counter on the local node for the link identified by ifIndex pppLqrConfigTable pppLqr 2 Not Accessible Table containing the LQR configuration...

Страница 120: ...anagement stations must be prepared to receive tabular information from agents that corresponds to entries not currently in use pppLqrExtnsTable pppLqr 3 Not Accessible Table containing additional LQR information for the local PPP entity The ATX always has an empty table pppLqrExtnsEntry pppLqrExtnsTable 1 Not Accessible Extended LQR information for a particular PPP Link Assuming that this group h...

Страница 121: ...ocol pppIpEntry 2 Integer Read only The IP compression protocol that the local PPP IP entity uses when sending packets to the remote PPP IP entity The value of this object is meaningful only when the link has reached the open state pppIpOperStatus is opened None 1 no IP compression protocol supported Vj tcp 2 the Van Jacobsen TCP IP header compression protocol is supported The ATX does not support...

Страница 122: ...Accessible Table containing configuration variables for the IPCP for the local PPP entity pppIpConfigEntry pppIpConfigTable 1 Not Accessible IPCP information for a particular PPP link pppIpConfigAdminStatus pppIpConfigEntry 1 Integer Read Write The immediate desired status of the IP network protocol Setting this object to open 1 will inject an administrative open event into the IP network protocol...

Страница 123: ...e status is not opened 2 pppBridgeLocalToRemoteTinygramCompression pppBridgeEntry 2 Integer Read Only Indicates whether the local node will perform Tinygram Compression when sending packets to the remote entity If false 1 then the local entity will not perform Tinygram Compression If true 2 then the local entity will perform Tinygram Compression The value of this object is meaningful only when the...

Страница 124: ...eOperStatus is opened pppBridgeConfigTable pppBridge 2 Not Accessible Table containing the parameters and statistics for the local PPP entity that are related to the operation of Bridging over the PPP pppBridgeConfigEntry pppBridgeConfigTable 1 Not Accessible Bridging configuration information for a particular PPP link pppBridgeConfigAdminStatus pppBridgeConfigEntry 2 Integer Read Write The immedi...

Страница 125: ...e 3 Not Accessible Table identifying which MAC media types are enabled for the Bridging NCPs pppBridgeMediaEntry pppBridgeMediaTable 1 Not Accessible Status of a specific MAC Type for a specific PPP Link pppBridgeMediaMacType pppBridgeMediaEntry 1 Integer Read Only The MAC type for which this entry in the pppBridgeMediaTable is providing status information Valid values for this object are defined ...

Страница 126: ...e is providing status information Valid values for this object are defined in Section 6 6 MAC Type Support Selection of RFC1220 Bridging Point to Point Protocol The unit only supports a MAC type of FDDI 4 pppBridgeMediaConfigLocalStatus pppBridgeMediaConfigEntry 2 Integer Read Write Indicates whether the local PPP Bridging Entity should accept 1 packets of the protocol type identified in pppBridge...

Страница 127: ...ntenance Protocol variables ZIP describes the Zone information Protocol variables NBP describes the Name Binding Protocol variables ATECHO describes the AppleTalk Echo Protocol variables For definitions of the variables refer to the sections that follow The MIB tree for reaching the AppleTalk MIB is 1 3 6 1 2 1 appletalk mib 2 13 9 1 LLAP GROUP The LLAP Group describes MIB variables related to the...

Страница 128: ...rs llapEntry 4 Counter Read Only The total number of good packets received on this LocalTalk interface for which there was no protocol handler llapInLengthErrors llapEntry 5 Counter Read Only The total number of packets received on this LocalTalk interface whose actual length did not match the length in the header llapInErrors llapEntry 6 Counter Read Only The total number of packets containing er...

Страница 129: ... received a packet with an FCS Frame Check Sequence error 9 2 AARP GROUP The AARP group describes MIB variables related to the AppleTalk Address Resolution Protocol aarp appletalk 2 aarpTable aarp 1 Not Accessible The AppleTalk Address Translation Table contains an equivalence of AppleTalk Network Addresses to the link layer physical address aarpEntry aarpTable 1 Not Accessible Each entry contains...

Страница 130: ...leTalk ports for this entity atportEntry atportTable 1 Not Accessible The description of one of the AppleTalk ports on this entity atportIndex atportEntry 1 Integer Read Only A unique value for each AppleTalk port Its value is between 1 and the total number of AppleTalk ports The value for each port must remain constant at least form the re initialization of the entity s network management system ...

Страница 131: ... value for atportNetEnd shall be two octets of zero atportNetAddress atportEntry 6 Octet String Read Write The AppleTalk network address configured for this port atportStatus atportEntry 7 Integer Read Write The configuration status of this port Setting this object to the value invalid 4 has the effect of invalidating the corresponding entry in the atportTable That is it effectively disassociates ...

Страница 132: ... associated with this AppleTalk port The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex 9 4 DDP GROUP The DDP group describes MIB variables related to the Datagram Delivery Protocol ddp appletalk 4 ddpOutRequests ddp 1 Counter Read Only The total number of DDP datagrams which were supplied to DDP by local DDP clients in req...

Страница 133: ...grams ddp 6 Counter Read Only The total number of input DDP datagrams for which this entity was their final DDP destination ddpNoProtocolHandlers ddp 7 Counter Read Only The total number of DDP datagrams addressed to this entity that were addressed to an upper layer protocol for which no protocol handler existed ddpOutNoRoutes ddp 8 Counter Read Only The total number of DDP datagrams dropped becau...

Страница 134: ...Read Only The total number of input DDP datagrams dropped because this entity was not their final destination and their type was short DDP ddpHopCountErrors ddp 13 Counter Read Only The total number of input DDP datagrams dropped because this entity was not their final destination and their hop count would exceed 15 ddpChecksumErrors ddp 14 Counter Read Only The total number of input DDP datagrams...

Страница 135: ...orm as DdpAddress rtmpType rtmpEntry 4 Integer Read Write The type of network over which this route points rtmpPort rtmpEntry 5 Integer Read Write The index of the AppleTalk port over which this route points rtmpHops rtmpEntry 6 Integer Read Write The number of hops required to reach the destination network to which this routing entry pertains rtmpState rtmpEntry 7 Integer Read Write The status of...

Страница 136: ...able 1 Not Accessible An entry of zone information for a particular zone and network combination zipZoneName zipEntry 1 Octet String Read Write The ASCII zone name of this entry zipZoneIndex zipEntry 2 Integer Read Only An integer that is unique to the zipZoneName that is present in this entry For any given zone name every zipEntry that has an equal zone name will have the same zipZoneIndex zipZon...

Страница 137: ...t is it effectively disassociates the mapping identified with said entry It is an implementation specific matter as to whether the agent removes an invalidated entry from the table Accordingly management stations must be prepared to receive from agents tabular information corresponding to entries not currently in use Proper interpretation of such entries requires examination of the relevant zipZon...

Страница 138: ... of this NBP entry Setting this object to the value invalid 2 has the effect of invalidating the corresponding entry in the nbpTable That is it effectively disassociates the mapping identified with said entry It is an implementation specific matter as to whether the agent removes an invalidated entry from the table Accordingly management stations must be prepared to receive from agents tabular inf...

Страница 139: ...ATEcho Group ATX MIB Reference Guide 9 13 atechoReplies atecho 2 Counter Read Only The number of AppleTalk echo replies sent ...

Страница 140: ...Chapter 9 AppleTalk MIB 9 14 ATX MIB Reference Guide ...

Страница 141: ...rs which are likely to be applicable for all of the products in the ATX product lines A detailed description of the parameters follows sysID sys 1 Integer Read Only An integer which serves to identify the type of hardware platform This document describes the ATX bridge router which uses the value 1 for sysID sysReset sys 2 TimeTicks Read Write The time in centiseconds before the ATX should reboot ...

Страница 142: ...ys 6 Integer Read Write Zero or the UDP port number to which a second copy of SNMP traps should be sent Valid values are 0 through 65535 10 2 RESERVED GROUP sigma 2 Not Applicable This subtree holds information which is not relevant for the unit 10 3 ATX GROUP ecs 1 sigma 3 This subtree holds all of the information for the unit These attributes are sheltered within a single tree in an attempt to a...

Страница 143: ...opulated This number is fixed as 7 hwSlotTable hw 2 Not Accessible A list of the most recent occupants of the slots one per slot hwSysBus hw 3 Integer Read Only hwPpeType hw 4 Integer Read Only hwSysProcessor hw 5 Integer Read Only hwEntry hwSlotTable 1 Not Accessible A set of objects for each slot The individual components are described below hwIndex hwEntry 1 Integer Read Only The slot number be...

Страница 144: ...ng IOM fddi iom 8 FDDI IOM ifddi iom 9 Intelligent FDDI IOM ttpr iom 10 Turbo Token Passing Ring IOM e g the QTIOM hwUseMod hwEntry 3 Integer Read Write Whether to use this module not applicable for the Packet Processing Engine The value of hwUseMod is not saved if the unit reboots see rebootUseMod If the module fails diagnostics it will not be used regardless of hwUseMod Possible values include r...

Страница 145: ...ues include diag failed 1 diagnostics failed diag not present 2 module not present or possibly diagnostics still running or the module s diagnostics are totally non responsive diag passed 3 diagnostics passed hwInuse hwEntry 6 Boolean Read Only Whether the module is currently executing its operational software hwDiagCode hwEntry 7 Octet String Read Only Additional diagnostics information concernin...

Страница 146: ...emaphore error 0x08000 reserved 0x10000 Packet Processing Engine Arbitration error For the Turbo processor board any combination of the following errors may be combined however any error will prevent the board from being used 0x00001 VDRAM and or Processor error 0x00002 Shared Ram error 0x00004 Rom Checksum error 0x00008 reserved 0x00010 reserved 0x00020 reserved 0x00040 UART error 0x00080 Cam err...

Страница 147: ...ce Strip Logic error 0x00800 FIOM Arbitration error 0x01000 Data Access Exception error For the intelligent FDDI IOM board IFIOM any combination of the following errors may be combined however any error will prevent the board from being used 0x00001 Local RAM error 0x00002 Shared RAM error 0x00004 Descriptor RAM error 0x00008 ROM Checksum error 0x00010 ID EEPROM Checksum error 0x00020 UART error 0...

Страница 148: ... 0x00200 Sonic error 2nd Sonic only if present 0x00400 Sonic error 3rd Sonic only if present 0x00800 Sonic error 4th Sonic only if present For the Token Ring 802 5 IOM boards including the single port Token Ring board and the four port Turbo Token Ring board any combination of the following errors may be combined however any error will prevent the board from being used 0x00001 Local SRAM error 0x0...

Страница 149: ...4 byte array which contains the part number serial number and hardware revision level of this unit The Turbo s hwManufData will be all blanks since it is manufactured as part of the Packet Processing Engine module hwPortType hwEntry 9 Integer Read Only A 4 byte array each element represents the port types belonging to this module The Packet Processing Engine s ports are fixed as uart for the first...

Страница 150: ...ting the unit hwAddr1 hwEntry 13 MacAddress Read Only The unique hard wired 48 bit MAC address for the module s 1st port For the Packet Processing Engine it s a unique MAC address to be used as part of the unit s Spanning Tree Bridge Identifier Not applicable for the Turbo hwAddr2 hwEntry 14 MacAddress Read Only A unique hard wired 48 bit MAC address for the modules s 2nd port only applicable for ...

Страница 151: ... module The element value is zero if the port is not present or does not have any repeater capability otherwise the value indicates the number of repeater ports at that port see rptrBasGroupNumOfPorts hwPortSubType hwEntry 21 Octet String Read Only A 4 byte array where each element represents additional port type information The following values have been defined 0x01 CSMA CD AUI 0x02 CSMA CD TP r...

Страница 152: ...e shielded and one unshielded 0x30 HSSI port with dual jacks one HSSI one RS 449 for lower speeds 0x40 FDDI DAS port with Single Mode fiber 0x41 FDDI DAS port with Multimode fiber 0x42 FDDI DAS port with Single Mode fiber on Mic A and Multimode fiber on Mic B 0x43 FDDI DAS port with Multimode fiber on Mic A and Single Mode fiber on Mic B 0xff Port not present or no additional information is availa...

Страница 153: ...ware module Since IOM hardware modules may be re started after the unit has booted the software which is executing on an IOM may be different than the software that was used when the unit booted swFileset swFilesetTable 1 Not Accessible A set of objects for each file set The individual components are described below swIndex swFileset 1 Integer Read Only The file set number beginning with 1 for the...

Страница 154: ...ligent FIOM Code ttiom 9 Turbo Token Ring IOM Code swSizes swFileset 6 Octet String Read Only An array 4 octets per file containing the size of each of the files Each size is encoded as a series of 4 bytes which should be converted into a 32 bit integer swStarts swFileset 7 Octet String Read Only An array 4 octets per file containing the software s execution starting address of each of the files E...

Страница 155: ...is a 32 byte array which contains information about the cause of the previous system reset This will describe the circumstances which forced the system software to perform a reboot The values in the first byte have the following meanings 0 Power failure remaining 31 bytes are not applicable 1 Watchdog Timeout next byte contains the hwIndex of the module which stopped responding remaining 30 bytes ...

Страница 156: ... sent to the NMS last heard from configFunctions config 5 Integer Read Only A bit field which describes the software functions supported by the unit The possible values or combinations thereof are 0x0001 NMS communicates with NMS 0x0002 TBRIDGE Transparent IEEE 802 1d MAC bridging if SBRIDGE is also set then SRT MAC bridging is supported 0x0004 SBRIDGE Source Routing MAC bridging 0x0008 MESH reser...

Страница 157: ...IPROUTER is set then this enables Proxy ARP RFC 1027 0x0400 IPX IPX routing is supported 0x0800 ARP 0x4000 BOOTP 0x8000 FRAME_SWITCH 0x10000 TRUNKING 0x20000 IPM multicast 0x40000 APPLETALK configPowerAc1 config 6 Boolean Read Only Whether the first power supply has AC input configPowerAc2 config 7 Boolean Read Only Whether the second power supply has AC input configPowerDc1 config 8 Boolean Read ...

Страница 158: ...erprise specific trap PDUs to be generated configStarageFailure config 14 Boolean Read Only Whether the unit s storage facility for its configuration parameters has failed the unit may not be able to reboot after such a failure configAuthenticationFailure config 15 IPAddress Read Only All nulls or the IP source address within the last SNMP PDU which caused an SNMP authentication failure configFddi...

Страница 159: ...tecting a fatal error See configDumpModule and configDumpEnd configDumpEnd config 21 Integer Read Write Ending address of memory to dump upon detecting a fatal error See configDumpModule and configDumpStart 10 3 3 2 LMA Configuration Group lma admin 2 This group of variables is used by the NMS to learn and modify the configuration status of the unit s Local Management Agent lmaAllAddr lma 1 MacAdd...

Страница 160: ...e for the PPE to create packets ppeUxTxCnt ppe 3 Integer Read Write The maximum number of received packets destined to the unit itself versus those received packets to be forwarded which can be stored until the PPE is able to process them ppeSmlBuffSize ppe 4 Integer Read Write The size in bytes of the PPE s small data buffers ppeBridgingMemory ppe5 Integer Read Only The percentage 1 99 of the PPE...

Страница 161: ...ress entries will be used for routing related addresses ppeTxCongests ppe 8 Counter Read Only Number of packets not received due to internal buffer congestion ppeArpEntries ppe 9 Counter Read Only Number of ARP entries for all interfaces ppeArpStatics ppe 10 Counter Read Only Number of statistically defined ARP entries for all interfaces ppeArpOverflows ppe 11 Counter Read Only Number of times a A...

Страница 162: ...nteger Read Write The value to assign to ipRouteMetric2 when adding a RIP learned entry to the IP Routing Table The route preference value for a RIP learned entry is 4 Note that for route preferences the smaller the value the higher the preference ppeEgpPreference ppe 17 Integer Read Write The value to assign to ipRouteMetric2 when adding an EGP learned entry to the IP Routing Table The route pref...

Страница 163: ...ul attempt to allocate from the routing table heap ppePacketMemorySize ppe 24 Counter Read Only Number of bytes originally given to the packet heap ppePacketMemoryAvail ppe 25 Counter Read Only Number of bytes currently available in the packet heap ppePacketMemoryfailures ppe 26 Counter Read Only Number of unsuccessful attempts to allocate from the packet heap This value is always zero for Release...

Страница 164: ...unter Read Only Number of times memory was allocated for a RIP PDU ppeBootpPduMemoryFailures ppe 33 Counter Read Only Number of unsuccessful attempts to allocate memory for a BOOTP PDU ppeBootpPduMemoryAllocs ppe 34 Counter Read Only Number of time memory was allocated for a BOOTP PDU ppeSnmpPduMemoryFailures ppe 35 Counter Read Only Number of unsuccessful attempts to allocate memory for an SNMP P...

Страница 165: ...es ppe 41 Counter Read Only Number of unsuccessful attempts to allocate memory for a ARP PDU ppeArpPduMemoryAllocs ppe 42 Counter Read Only Number of time memory was allocated for a ARP PDU ppeIgmpPduMemoryFailures ppe 43 Counter Read Only Number of unsuccessful attempts to allocated memory for a IGMP PDU ppeIgmpPduMemoryAllocs ppe 44 Counter Read Only Number of times memory was allocated for a IG...

Страница 166: ...roupAddr will not take effect until the unit reboots stResAddr st 2 OctetString Read Write A series of 90 octets containing the Spanning Tree s 15 reserved addresses 01 80 c2 00 00 01 through 01 80 c2 00 00 0f Changing stResAddr will not take effect until the unit reboots stBridgeId st 3 Obsolete stRootMaxAge st 4 Obsolete stRootHello st 5 Obsolete stRootDelay st 6 Obsolete stRootId st 7 Obsolete ...

Страница 167: ...ast reset by the NMS stTopChangeTime st 15 TimeTicks Read Only If stTopChange is True then the time since stTopChange changed from False to True If stTopChange is False then the time since stTopChange changed from True to False stAgeTime st 16 Obsolete 10 3 3 5 Mesh Group mesh admin 5 This optional group contains the unit wide parameters which control the Cabletron Mesh algorithm Since the MESH bi...

Страница 168: ...nloaded Attempts to download other versions of software will be rejected The value for swdisAccess is embedded within the software files that are to be distributed via TFTP Its value may be derived from the names of the software files For example file name dnld_hdr 10 2 indicates that the file contains Version 10 2 software The corresponding value for swdisAccess would be 523 and can be determined...

Страница 169: ...ddress of the NMS i e any IP host that is allowed to use TFTP to send retrieve the configuration file of the ATX A value of 0 0 0 0 which is the factory specified default prevents any NMS from obtaining access while a value of 255 255 255 255 gives every NMS permission swdisConfigRetryTime swdis 5 Integer Read Write The number of seconds that the ATX will wait for an acknowledgment before it retra...

Страница 170: ...tron Mesh Algorithm bridge addresses The addrIndexMesh parameter does not have to be reset between successive read next operations Step 3 Set addrOperation with the read next operation code This will cause the ATX to update the Addresses Configuration Group fields about the entry which includes updating addrNext to contain the value for addrIndex if one desires to obtain the next entry addrNext wi...

Страница 171: ...ic or entry none or entry mesh For entry static and entry none either or both of entry no source and entry no multi may be set Use of entry mesh is reserved for the future The entry will be deleted if there is no learned information when the ATX is told to set addrOperation to update unless any of the following is true entry static is set entry no source is set entry no multi is set Step 3 If the ...

Страница 172: ...ain the next block of entries addrNext will be set to 1 if there is no next block Step 3 Set the desired fields typically addrNext addrBlockSize and addrBlock to NULL within the SetRequest PDU or issue a GetRequest s for the desired fields Many of the Addresses Configuration Group parameters have an access code of Write Ignore which is like Read Only since the parameters values are not changed by ...

Страница 173: ...try mesh however for GetRequests the NMS will see either no bits set if the entry does not exist or exactly one of the following bits set entry dynamic local 30 if set then this is a dynamically learned customer address which exists on one of this ATX s ports entry dynamic remote 29 if set then this is a dynamically learned customer address which can be reached via additional ATM Frame Relay or SM...

Страница 174: ...to the LMA and forwarded throughout the bridged network only if the receiving port is in the proper state The IEEE Spanning Tree All LANs Bridge Management Group Address should be the only instance of this entry entry any lma 16 if set then this is an address for packets to be sent to the LMA regardless of the receiving port s state This is reserved for future enhancements entry lma 15 reserved fo...

Страница 175: ...on ports only valid for entry static entries Within each set of four octets each bit is set if a packet with a matching destination address may be forwarded to that port For example bits 21 2 of the 9th 10th 11th and 12th octets correspond to ports 21 2 for packets received by port 2 Since only the ATX s ports 2 through 21 are available for bridging all unused bits i e bits 0 1 and 22 through 31 o...

Страница 176: ... addr 15 Obsolete addrCost3 addr 16 Obsolete addrCost4 addr 17 Obsolete addrSource1 addr 18 Obsolete addrSource2 addr 19 Obsolete addrSource3 addr 20 Obsolete addrSource4 addr 21 Obsolete addrDest1 addr 22 Obsolete addrDest2 addr 23 Obsolete addrDest3 addr 24 Obsolete addrDest4 addr 25 Obsolete addrStabile addr 26 Obsolete ...

Страница 177: ... Obsolete addrOldSource1 addr 31 Obsolete addrOldSource2 addr 32 Obsolete addrOldSource3 addr 33 Obsolete addrOldSource4 addr 34 Obsolete addrOldDestination1 addr 35 Obsolete addrOldDestination2 addr 36 Obsolete addrOldDestination3 addr 37 Obsolete addrOldDestination4 addr 38 Obsolete addrOldTxSource addr 39 Obsolete addrOldTxDestination addr 40 Obsolete ...

Страница 178: ...en ATM Frame Relay or SMDS is implemented this will indicate whether any type of entry false should be returned for read next operation or just ATM Frame Relay or SMDS addresses true addrNext addr 44 Integer Write Ignore The next value to use for addrIndex when you use read next or read block operations to read the address table When the ATX boots addrNext is initialized to 1 addrAge addr 45 TimeT...

Страница 179: ... Write Ignore The number of packets received from the address which were forwarded can be zeroed by zero stats This includes packets that were MAC layer bridged because they were received on a port that was in Spanning Tree forwarding state and packets that were routed regardless of the port s Spanning Tree state addrTxPkts addr 50 Counter Write Ignore The number of packets transmitted to the addr...

Страница 180: ...alid if the port s srepeaterExtendedStats is enabled and if the unit s ppeExtendStats is true 10 3 6 SNMP SMT Support Group snmpsmt ecs 1 6 This parameter group supplies the NMS with a way to access FDDI devices that support SMT services but not SNMP services The NMS requests a unit which must be on the FDDI ring to perform an SMT query response exchange with the desired FDDI device To build an FD...

Страница 181: ...nit converts it into a big endian FDDI address and issues an SMT NIF request to determine that address s upstream neighbor When the NIF response is received snmpsmtUpstreamRsp will hold the address of the upstream neighbor and a trap will be sent to the NMS fddismtUpstreamRsp fddismtEntry 3 MacAddress Read Only The address of the upstream neighbor of the unit whose address was written into snmpsmt...

Страница 182: ...ich are not defined in the standard MIBs sifUX sinterfaces 1 Integer Read Only The maximum number of receive data buffers supported by the unit The sum of sifSmIRxCnt and sifLrgRxCnt for all ports plus ppeSmlRxCnt and ppeLrgRxCnt must be less than or equal to sifUX sifTable sinterfaces 2 Not Accessible A list of interface entries one per port sifEntry sifTable 1 Not Accessible A set of objects for...

Страница 183: ...ead Write The time period in seconds to which sifThreshold applies A value of zero will disable the sifThreshold alarm sifRxQueueThresh sifEntry 7 Integer Read Write Maximum number of receive packet queue overflow errors before an alarm should be generated sifRxQueueThreshTime sifEntry 8 Integer Read Write The time period in seconds to which sifRxQueueThresh applies A value of zero will disable th...

Страница 184: ...pre defined destination address sifCongestTime sifEntry 12 TimeTicks Read Write When a port becomes congested the PPE will discard any packets destined to the port for this many centiseconds following the congestion alarm Possible values are 0 through 5 minutes except for port 1 the out of band management port which is always 0 sifQueueTime sifEntry 13 TimeTicks Read Write The time in centiseconds...

Страница 185: ...ents will most likely be flooded with duplicates of packets 0x0040 RIP shows if RIP is enabled on the port for IP Routing see sprotoRip 0x0080 SRSPAN shows if auto span is enabled on the port for SR or SRT bridging see dot1dSrPortSTESpanMode 0x0100 PROXY shows if Proxy ARP is enabled on the port for IP Routing see sprotoArpProxy 0x0400 IPX routing shows if the port is enabled for IPX routing see s...

Страница 186: ...n into 25 categories The number of packets in each category is encoded as a series of 4 bytes which should be converted into a 32 bit counter The 25 categories are determined by combining each possible DEST_xxx value with each possible OUTCOME_xxx value as listed below DEST_UBRIDGE 0 a bridge management unicast address DEST_MBRIDGE 1 a bridge management multicast address DEST_KNOWN 2 a known non m...

Страница 187: ...th invalid contents may cause DEST_MULTI DEST_KNOWN to be set for an intended DEST_MBRIDGE DEST_UBRIDGE type of packet OUTCOME_DEST 20 packet filtered destination port restriction sifRxChar0s sifEntry 24 Counter Read Only Number of characters in the forwarded received packets sifRxChar1s sifEntry 25 Counter Read Only Number of characters in the filtered received packets sifRxSizeErrors sifEntry 26...

Страница 188: ...ulticast storm sifTxDests sifEntry 33 Counter Read Only Number of packets not sent due to a destination port filtering restriction sifErrorsFlag sifEntry 34 Boolean Read Only Whether the port has exceeded the limits specified by sifThreshold and sifThresholdTime sifTxStormFlag sifEntry 35 Boolean Read Only Whether PPE has invoked multicast storm protection sifTxSizes sifEntry 36 Counter Read Only ...

Страница 189: ...ected In particular the following statistics may be examined to determine the exact utilization rate of a port ifInOctets ifInUcastPkts ifInNUcastPkts ifOutOctets ifOutUcastPkts ifOutNUcastPkts sifRxChars0s sifRxChars1s sifIpAddress sifEntry 40 IP Address Read Write The IP address assigned to the port If this is zero then the port must learn its IP address via Reverse ARP or PPP s IPCP sifIpGroupA...

Страница 190: ...ally polled rather than recalculated whenever a packet is added so sifInQLen is an approximation of the maximum length sifFrameSwitching sifEntry 46 Integer Read Write Valid for Token Ring ports Options include enabled 1 disabled 2 Default is disabled 2 If enabled frames may be bridged between token ring ports on the same board at higher throughput and lower latency than is otherwise possible Addr...

Страница 191: ...fddiEntry 1 Integer Read Only The unit s port number of the port sfddiRxHwAborts sfddiEntry 2 Counter Read Only The number of packets that were discarded due to receive abort errors sfddiRxParitys sfddiEntry 3 Counter Read Only The number of packets that were discarded due to parity errors sfddiRxShorts sfddiEntry 4 Counter Read Only The number of packets that were discarded because they were too ...

Страница 192: ...00000001 RING any change in the status of Ring_Op 0x00000002 CLAIM receipt of My_Claim Higher_Claim or Lower_Claim 0x00000004 BEACON receipt of My_Beacon or Other_Beacon 0x00000008 TVX expiration of tvx 0x00000010 TRT expiration of TRT and Late_ct non zero 0x00000020 PHY INVALID receipt of PH_Invalid causing the receiver to enter state R0 this bit indicates that the Link Error Rate Threshold Test ...

Страница 193: ...rted to the NMS via SNMP Traps For those SRF policies which are optional i e SRF_NOT_COPIED SRF_EB_ERROR and SRF_TRACE the setting of a bit also indicates that the policy is to be implemented Possible values include any combination of the following bits 0x00000001 SRF FRAME ERROR the MAC frame error rate exceeded the threshold rate 0x00000002 SRF PORT LER a port s LER Alarm has been triggered 0x00...

Страница 194: ...ee chapter 11 sfddiSrfReportLimit sfddiEntry 15 Obsolete sfddiFrameErrorThreshold sfddiEntry 16 Obsolete sfddiNotCopiedThreshold sfddiEntry 17 Integer Read Write Value for the fddiMACNotCopiedThreshold variable sfddiSBFlag sfddiEntry 18 Boolean Read Only Whether the ECM s optical bypass is stuck i e the current value of the SMT SB_Flag variable sfddiRxEbits sfddiEntry 19 Counter Read Only The numb...

Страница 195: ...0400 Twisted Ring set when a A A connection is detected in the station x00000800 Twisted Ring set when a B B connection is detected in the station x00001000 Rooted Station set when the station does not have an active A B or S port in tree mode x00002000 Status Report set if SRF protocol is enabled fddiSMTStatRptPolicy The following bits indicate one or a combination of duplicate address conditions...

Страница 196: ...cessible A set of objects for an interface entry The individual components are described below suartIndex suartEntry 1 Integer Read Only The ATX s port number of the port suartBaud suartEntry 2 Integer Read Write This is the desired baud rate Only 1200 baud through 19 200 baud are supported by the ATX but the complete set of possibilities is external clock 1 1200 baud 2 2400 baud 3 4800 baud 4 960...

Страница 197: ...ete the ATX s combination filters A combination filter consists of many tests that are simultaneously applied to a packet to determine if the packet should be filtered Several combination filters may exist Each combination filter i e each set of tests is used sequentially and the packet is filtered if any of the combination filters determine that the packet should be filtered Two sequential series...

Страница 198: ...eld to contain the value of the filter s filter ID Once the ATX receives this SetRequest the ATX renumbers all of the filters thereby invalidating the NMS s combination filters information Step 3 Optionally reread all of the combination filters To add a new combination filter for a port the NMS must perform the following steps Step 1 Determine the next available filterIndex filterCurrentCount plus...

Страница 199: ...terCurrentCount filterNextID and the entire filterTable filterNextID filter 4 Integer Read Only A filter identifier used for adding filters See filterAddID filterAddID filter 5 Integer Read Write A filter identifier used for adding filters After the NMS sets this field the ATX adds the filterEntry indexed by filterAddIndex The ATX then updates filterCurrentCount filterNextID and the entire filterT...

Страница 200: ...ly Identifier assigned to the filter used for obtaining the value for filterDeleteID so that the filter can be deleted filterPortNo filterEntry 3 Integer Read Write The port number related to this filter filterComboType filterEntry 4 Integer Read Write Whether this is an entry filter 0 or an exit filter 1 type filterFlags filterEntry 5 Integer Read Write A set of flag bits which control the operat...

Страница 201: ...LCM as a pseudo filter bit 10 used to determine if this filter should be combined if set this filter should be combined using the or operator with the next filter of the same filterComboType for the same filterPortNo bits 9 8 used for filterFrame bit 9 if set filter if match bit 8 if set filter if not match bits 7 6 used for filterSource filterSourceEnd and filterSourceMask bit 7 if set filter if ...

Страница 202: ...ginning source address filterSourceEnd filterEntry 8 MAC Address Read Write Ending source address filterDest filterEntry 9 MAC Address Read Write Beginning destination address filterDestEnd filterEntry 10 MAC Address Read Write Ending destination address filterSourceMask filterEntry 11 MAC Address Read Write A bitmask to be applied to the packet s source address before checking it against filterSo...

Страница 203: ...e An 8 octet value to be compared to the contents of the arbitrary field within the packet filterMask filterEntry 16 Octet String Read Write An 8 octet mask to be applied to the arbitrary field within the packet before comparing it to filterField filterThreshold filterEntry 17 Integer Read Write The number of filter invocations at which an alarm to the NMS should be generated filterThreshTime filt...

Страница 204: ...with the packet s contents filterFast filterEntry 22 Obsolete 10 3 11 Change Reboot Characteristics Command Group reboot ecs 1 11 The set of reboot characteristics includes how to partition the PPE s memory for bridging versus routing and the module types and port types The NMS may change any of these characteristics while the unit is running however none of them will be applied until the unit reb...

Страница 205: ...t represents the types of the ports belonging to this module see hwPortType rebootConfig reboot 3 Integer Read Write The configuration file that will be used when the unit reboots This parameter is normally automatically set by the unit however an NMS may explicitly set it to either no change 1 or revert to defaults 3 The possible values include no change 1 the unit will not change its configurati...

Страница 206: ...memory locations Step 4 Set debugOperation with the DEBUG_EXAMINE value All of the above sets must be performed in a single SetRequest PDU with debugOperation being the last parameter This will cause the ATX to read the desired memory locations update the debugLength and debugData parameters and return the updated parameters in the GetResponse PDU To modify a ATX s memory the NMS must perform the ...

Страница 207: ...bug 2 Octet String Read Only The last debug text string 0 80 bytes sent by the unit debugTable debug 3 Not Accessible A list of the modules which may be debugged with one module per slot defined by hwSlotTable debugEntry debugTable 1 Not Accessible A set of objects for each module The individual objects are described below debugIndex debugEntry 1 Integer Read Only The module number beginning with ...

Страница 208: ...data supplied by the NMS 10 3 13 Loopback Command Group lpbk ecs 1 13 The NMS may initiate terminate local or remote loopback on a port In local loopback the port is disconnected from its network The ATX generates loopback packets for the port and the port loops back packets without sending them onto its network In remote loopback the port is in normal operation sending receiving normal packets In...

Страница 209: ... local Also the port must be enabled according to ifOperStatus Step 2 Wait for the GetResponse PDU Step 3 If the GetResponse did not indicate an error then wait for and acknowledge the enterprise specific trap that contains the lpbkOperation parameter Multiple traps may be sent if there are multiple errors A port s loopback operation is automatically terminated after the requisite number of packet...

Страница 210: ...ote loopback lpbkDestAddr lpbkEntry 3 MacAddress Read Write The MAC address of the target device only needed for remote loopback lpbkPktNum lpbkEntry 4 Integer Read Write The number of loopback packets to be transmitted lpbkInterval lpbkEntry 5 TimeTicks Read Write The desired time delay between the reception of a looped back packet and the transmission of the next packet to be looped back lpbkPkt...

Страница 211: ... caused either lpbkErrorNoReceives or lpbkErrorBadReceives to be incremented This number is automatically reset to zero whenever loopback operation is initiated lpbkErrorSent lpbkEntry 12 OctetString Read Only The transmitted bytes 0 4 of data within the last loopback packet which caused lpbkErrorBadReceives to be incremented This parameter is automatically reset to the null string whenever loopba...

Страница 212: ...ry 1 Integer Read Only The unit s port number of the port swanDesiredSpeed swanEntry 2 Obsolete swanActual Speed swanEntry 3 Integer Read Only This is the actual line speed The possible values are defined by suartSpeed For HSSI the speed is 45 megabits 11 If the RS 449 interface is being used on the HSSI IOM the speed is always reported as 1 544 megabits 9 however the external clock may be generat...

Страница 213: ...y 12 Obsolete swanLinkPort swanEntry 13 Obsolete swanNegotiate swanEntry 14 Obsolete swanSwitches swanEntry 15 Integer Read Write Current port selected Possible values include wan hssi 1 HSSI is selected wan t1 2 RS 449 is selected wan hssi switching disabled 3 HSSI is selected and cannot be switched to RS 449 except by NMS interaction wan t1 switching disabled 4 449 is selected and cannot be swit...

Страница 214: ...eaterGroupID is assigned so as to uniquely identify a repeater in a system where a single agent manages multiple repeaters Values range from 1 to 1024 srepeaterLinkStatusMask srepeaterEntry 2 Integer Read Only This mask provides quick access to the general connectivity of the repeater Each bit corresponds to the link status of a repeater port If the bit is 1 then the link pulses are being received...

Страница 215: ... repeater port in the system srepeaterPortGroupID srepeaterPortEntry 1 Integer Read Only The value of srepeaterPortGroupID is assigned so as to uniquely identify a repeater in a system where a single agent manages multiple repeaters This corresponds to ifIndex as well as rptr GroupIndex srepeaterPortPortID srepeaterPortEntry 2 Integer Read Only This variable identifies the port within the repeater...

Страница 216: ...specifies the type of framing to be used for NetWare IPX packets on 802 3 networks ethernet8023 1 specifies that the 802 3 header is to be used without an 802 2 header ethernet2 2 specifies that Ethernet 2 framing is to be used with ethernet Type 8137 ethernet8022 3 specifies that an LLC header e0 e0 03 is to be used in conjunction with the 802 3 header sprotoEntry sprotoTable 1 Not Accessible Eac...

Страница 217: ... Write Allows transmission of spanning tree protocol packets to be suppressed If norman 1 802 1d spanning tree packets and source routing spanning tree packets are transmitted as usual If suppressed 2 these packets are not transmitted This option may be needed for interoperability with non 802 1d spanning tree protocols e g DEC LanBridge 100 sprotoIpRoute sprotoEntry 4 Integer Read Write Specifies...

Страница 218: ...neto6swap 6 then in coming type 6ARP packets will be converted to type 1 and outgoing type 1ARP packets will be changed to type 6 with embedded addresses bitswapped This option only applies to Token Ring ports The factory default for all ports is none 1 Values other than 1 and 6 are deprecated sprotoArpSourceRoute sprotoEntry 8 Integer Read Write Specifies whether when bridging IP ARP packets whic...

Страница 219: ...ts Either enabled 1 disabled 2 sprotoIbmLlcTranslate sprotoEntry 11 Integer Read Write Specifies whether when bridging IBM LLC frames an 8209 style translation between Token Ring and Ethernet format is to be performed before being forwarded This option only applies to Token Ring ports Either enabled 1 disabled 2 sprotoRip sprotoEntry 12 Integer Read Write Specifies whether the internet Routing Inf...

Страница 220: ... disabled 2 sprotoIbm8209Lsaps sprotoEntry 16 Octet String Read Write Specifies up to eight LSAPs for which IBM 8209 style Token Ring to Ethernet encapsulation is to be performed Only valid if sprotoIbmLlcTranslate is enabled sprotoBootpRelay sprotoEntry 17 Integer Read Write Specifies whether or not this port is to relay BOOTP packets as described in RFC 951 and subsequent internet drafts Only va...

Страница 221: ... 19 Integer Read Write Specifies whether the internet Multicast Routing Protocol is to be used over this port Only valid if sprotoIpRoute is enabled sprotoTrunking sprotoEntry 20 Integer Read Write Specifies whether Cabletron s trunking protocol an extension to the standard Spanning Tree Bridging protocol is to be used over this port 10 3 18 Cabletron IPX Group sipx ecs 1 18 This group contains th...

Страница 222: ...et links ethernet2 2 framing uses an Ethernet type of hexadecimal 8137 followed by the IPX data ieee8022 3 framing uses DSAP and LSAP fields of hexadecimal e0 followed by a control byte of 03 unnumbered information followed by the IPX data This is the default for non Ethernet links Ethernet links precede the SAPs with an Ethernet length snap 4 framing uses standard SNAP encapsulation of the 8137 E...

Страница 223: ...ible Each entry indexed by sipxRouteDest is a route to a particular destination sipxRouteDest sipxRouteEntry 1 Octet String Read Only The destination network address of this route sipxRouteIfIndex sipxRouteEntry 2 Integer Read Only The index value which uniquely identifies the local interface through which the next hop of this route should be reached The interface identified by a particular value ...

Страница 224: ...AP Table sipxSapTable sipx 3 Not Accessible This table contains an entry for each SAP cache service presently known to this router sipxSapEntry sipxSapTable 1 Not Accessible Each entry indexed by sipxSapIndex is an IPX service definition as advertised by the SAP protocol and distributed through the SAP cache of this router sipxSapIndex sipxSapEntry 1 Integer Read Only Used only as an artificial in...

Страница 225: ...e socket number to which service requests should be addressed sipxSapHopCount sipxSapEntry 7 Integer Read Only A count of the number of routers that must be traversed to reach this server sipxDiscardedRoutes sipx 4 Counter Read Only A count of the number of received routes that were lost due to insufficient resources sipxDiscardedServices sipx 5 Counter Read Only A count of the number of received ...

Страница 226: ...de enabled 1 disabled 2 srtrdiscAdvertisementAddress srtrdiscEntry 3 Integer Read Write The IP address to be used for multicast router advertisements for this interface If multicast 1 the all systems multicast 224 0 0 1 is used If broadcast 2 the limited broadcast 255 255 255 255 is used srtrdiscAdvertisementInterval srtrdiscEntry 4 Integer Read Write The interval at which multicast router adverti...

Страница 227: ...nceptual row representing information on an origin route when IPM is enabled sipmRouteOrigin sipmRouteEntry 1 IP Address Read Only The subnetwork address of the origin sipmRouteOriginMask sipmRouteEntry 2 IP Address Read Only The subnetwork mask of the origin sipmRouteGateway sipmRouteEntry 3 IP Address Read Only The next hop gateway toward the origin This object has the value 0 0 0 0 for directly...

Страница 228: ...isting the neighboring routers on each interface port sipmNeighborEntry sipmNeighborTable 1 Not Accessible An entry of all neighbors which are learned from this local interface port sipmNeighborIfIndex sipmNeighborentry 1 Not Accessible The ifIndex value of the interface for which this entry contains information sipmNeighbors sipmNeighborEntry 2 IP Address Read Only The neighbor s IP address which...

Страница 229: ...he interface port number on which corresponding IPM statistics gather sipmStatBadPackets sipmStatEntry 2 Counter Read Write The number of bad packets received which may include unknown DVMRP IGMP messages short packets and checksum errors sipmCacheMiss sipmStatEntry 3 Counter Read Write The number of times IP Multicast packets need to lookup a route at the IP layer for determining forwarding path ...

Страница 230: ...ll default to standard class A B C mask depending on the value of sipcktIpAddress sipcktSourceRoute sipckEntry 5 Integer Read Write Specifies the behavior of IP routing with respect to link layer source routing for this circuit If default 1 then behavior depends on whether the port is token ring or not If token ring then ARP requests are sent both as source routing explorers and as local frames if...

Страница 231: ...Entry 1 Not Accessible The interface on which this entry s equivalence is effective The interface identified by a particular value of this index is the same interface as identified by the same value of ifIndex sipNetToMediaNetAddress sipNetToMediaEntry 2 Not Accessible The IP Address corresponding to the media dependant physical address sipNetToMediaSourceRoute sipNetToMediaEntry 3 Octet String Re...

Страница 232: ...trunking PDUs oneway 3 incoming trunking PDUs do not indicate that the ATX s PDUs are being successfully received by the far end joined 4 this link is actively participating in the trunk group perturbed 5 this link is actively participating in the trunk group however the transmission of data packets has been temporarily stopped due to a change in membership of the trunk group helddown 6 an error h...

Страница 233: ...tocol will re start standby 5 this trunk group is filled to capacity using other ports this port is now a hot standby too many groups 6 the maximum number of groups an ATX can handle has been reached and a new group cannot be added This port will not be used until the condition clears no ack 7 this port has not received a valid trunking packet and the trunking protocol will re start perturbed thre...

Страница 234: ...onceptual table containing multicast routing information for IP datagrams sent by particular sources to the IP multicast groups known to this router ipMRouteEntry ipMRouteTable 1 Not Accessible An entry conceptual row containing the multicast routing information for IP datagrams from a particular source and addressed to a particular IP multicast group address ipMRouteGroup ipMRouteEntry 1 Not Acce...

Страница 235: ...re received ipMRouteOutList ipMRouteEntry 6 Integer Read Only The value of ipMRouteNextHopList which identifies the list of entries in the ipMRouteNextHopTable representing outgoing interfaces to which IP datagrams from this source to this multicast group address are forwarded ipMRouteUpTime ipMRouteEntry 7 TimeTicks Read Only The time since the multicast routing information represented by this en...

Страница 236: ...pMRoute 3 Not Accessible The conceptual table containing information on the outgoing interfaces and next hops for the routing IP multicast datagrams Each entry is one of a list of outgoing interface and next hops for a particular source and multicast group address ipMRouteNextHopEntry ipMRouteNextHopTable 1 Not Accessible An entry conceptual row containing a particular outgoing interface and next ...

Страница 237: ... interface and next hop ipMRouteNextHopUpTime ipMRouteNextHopEntry 6 TimeTicks Read Only The time since the multicast routing information represented by this entry was learned by the router ipMRouteNextHopExpiryTime ipMRouteNextHopEntry 7 TimeTicks Read Only The minimum time before this entry will be aged out 10 3 24 2 IPM Route Interface Table ipMRouteInterfaceTable ipMRoute 4 Not Accessible The ...

Страница 238: ...igmpInterfaceEntry IgmpInterfaceTable 1 Not Accessible An entry conceptual row representing an interface on which IGMP is enabled igmpInterfaceIfIndex IgmpInterfaceEntry 1 Integer Not Accessible The interface for which IGMP is enabled igmpInterfaceQueryInterval igmpInterfaceEntry 2 Integer Read Write The frequency at which IGMP Host Query packets are transmitted on this interface igmpInterfaceStat...

Страница 239: ...r the local system is a member of this group address on this interface igmpCacheLastReporter igmpCacheEntry 4 IP Address Read Only The IP address of the source of the last membership report received for this IP Multicast group address on this interface If no membership report has been received this object has the value 0 0 0 0 igmpCacheUpTime igmpCacheEntry 5 TimeTicks Read Only The time since the...

Страница 240: ...alk ports on this entity atextportIndex atextportEntry 1 Integer Read Only A unique value for each AppleTalk port Its value is between 1 and the total number of AppleTalk ports The value for each port must remain constant at least from the re initialization of the entity s network management system to the next re initialization atextportNetStart atextportEntry 2 Octet String Read Only The first Ap...

Страница 241: ...igured for a port atextportzipEntry atextportzipTable 1 Not Accessible An entry of zone information for a particular zone and port combination atextportZonePort atextportzipEntry 1 Integer Read Only A unique value for each AppleTalk port atextportZoneIndex atextportzipEntry 2 Integer Read Only An integer that is unique to the ZoneName that is present in this entry For any given zone name every Ent...

Страница 242: ...Chapter 10 Cabletron MIB 10 102 ATX MIB Reference Guide ...

Страница 243: ...fferent traps which are described below coldStart 0 A unit has re started and the NMS s copy of the unit s configuration may be incorrect warmStart 1 Not used by the unit linkDown 2 A port has failed and the unit s local management agent has disabled usage of the port The variable bindings portion of the trap contains the ifIndex of the port linkUp 3 A port has come back to life and the unit s loc...

Страница 244: ...or the variables associated with the Trap s cause Note that Acknowledge mode is only applicable for enterpriseSpecific traps that is only enterpriseSpecific traps may be re sent Many traps include additional variable bindings besides the variable binding which initiated the trap to be generated The additional variable bindings are not guaranteed to be present and or may be passed in separate Trap ...

Страница 245: ...RAPS Priority 1 Traps are the middle priority enterpriseSpecific Traps and are only sent if configAlarmDynamic is True except for swdisWriteStatus and swdisDesc Each of these Traps is acknowledged by reading every variable within the Trap unless otherwise indicated The following variables may be reported pppLinkQuality Sent whenever the PPP port is enabled and its link quality has changed from bad...

Страница 246: ...agStatus hwDiagCode does not need to be acknowledged hwManufData Sent in conjunction with hwDiagStatus or hwTempOK hwManufData does not need to be acknowledged hwType Sent in conjunction with hwDiagStatus hwType does not need to be acknowledged hwPortType Sent in conjunction with hwDiagStatus hwPortType does not need to be acknowledged hwPortStatus Sent in conjunction with hwDiagStatus hwPortStatu...

Страница 247: ...d mechanism for an authentication failure Therefore multiple occurrences of this trap indicate either multiple authentication failures or a failure to receive the trap acknowledgment ppeTxCongests Sent whenever packets destined for the unit itself were discarded due to lack of buffer space stRootID Sent whenever the unit s Spanning Tree Root Bridge ID has changed This MIB variable is obsolete stRo...

Страница 248: ...be acknowledged and is Obsolete sifFunctions Sent whenever the current functional state active protocols of the port has changed sifCongested Sent whenever outbound congestion control has been invoked for the port sifState Sent whenever the Spanning Tree state of the port has changed This is obsolete sifDesigCost Sent whenever the cost to the Spanning Tree Root Bridge from the designated port of t...

Страница 249: ... occurred The trap is acknowledged by a SetRequest Each bit that is set in the sfddiSmtConditionsStatus parameter within the SetRequest clears the corresponding alarm condition sfddiSrfConditionsStatus Sent whenever any of the indicated conditions has occurred The trap is acknowledged by a SetRequest Each bit that is set in the sfddiSrfConditionsStatus parameter within the SetRequest clears the co...

Страница 250: ...t Obsolete swanLinkBridge Obsolete swanLinkPort Obsolete srptrLinkStatusMask Sent whenever the status of any of a repeaters s port has changed This variable is obsolete 11 4 PRIORITY 2 TRAPS Priority 2 Traps are the lowest priority enterpriseSpecific Traps and are only sent if both configAlarmAddresses and configAlarmDynamic are True Each trap contains just the addrAlarmMAC parameter and is sent i...

Страница 251: ...grams of the IP UDP and TCP headers are provided here for your reference Figure A 1 IP Header Figure A 2 UDP Header After IP Header IP version header length service type total length identification flags fragment offset source IP address destination IP address IP options if any padding if necessary TTL protocol checksum UDP source port UDP destination port UDP message length UDP checksum ...

Страница 252: ...ion Procedure A 2 ATX MIB Reference Guide Figure A 3 TCP Header After IP Header acknowledgment number window options if any padding if necessary source port destination port sequence number header length reserved plus code bits ...