940
Brocade Network Advisor SAN User Manual
53-1003154-01
FCIP trunking
22
•
A valid failover group requires at least one metric 0 circuit and at least one metric 1 circuit. If
you do not configure these, a warning will display. If there is no metric 0 circuit and only a
metric 1 circuit, the metric 1 circuit will be used, regardless of whether there are metric 0
circuits in another failover group.
•
The number of valid failover groups defined per tunnel is limited by the number of circuits that
you can create for the switch model. For an 8 Gbps Extension Blade, you can configure up to 5
valid groups on an 10-circuit tunnel. On an 8 Gbps Extension Switch, you could have up to 3
valid groups because you can only configure 6 circuits per tunnel.
•
Consider available WAN bandwidth requirements when configuring failover circuit groups.
Refer to
“Bandwidth calculation during failover”
on page 938.
Examples of circuit failover in groups
Tables
Table 72
through
Table 74
provide examples of how failover occurs on circuits with different
bandwidths configured in failover groups.
Table 72
illustrates circuit failover in a tunnel with two failover groups, each with two circuits. All
data through the tunnel is initially load balanced over Circuits 1 and 2. The following occurs during
circuit failover:
•
If circuit 1 fails, circuit 3 becomes active and data is load balanced over circuit 2 and 3.
•
If circuit 2 fails, circuit 4 becomes active and data is load balanced over circuit 1 and 4.
•
If both circuit 1 and 2 fail, circuit 3 and.4 become active and data is load balanced over both
circuits.
Table 73
illustrates circuit failover in a tunnel with one failover group containing three circuits, In
this case, failover occurs as if circuits are not part of a failover group. Circuit 2 and 3, both with
metric 1, become active only after circuit 1 with metric 0 fails.
TABLE 72
Tunnel with two failover groups with two circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
500Mb
If active, yes.
Circuit 2
Metric 0
2
1000Mb
If active, yes.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 4
Metric 1
2
1000Mb
Only when circuit 2
fails.
TABLE 73
Tunnel with one failover groups with three circuits
Circuits in tunnel
Failover group ID
Circuit bandwidth
In use for tunnel data
Circuit 1
Metric 0
1
1000Mb
If active, yes.
Circuit 2
Metric 1
1
500Mb
Only when circuit 1
fails.
Circuit 3
Metric 1
1
500Mb
Only when circuit 1
fails.
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...