1606
Brocade Network Advisor SAN User Manual
53-1003154-01
Database tables and fields
H
TABLE 174
HBA_REMOTE_PORT
Field
Definition
Format
Size
ID Autogenerate
primary
column.
int
SYMBOLIC_NAME
The symbolic name associated with the remote port.
varchar
256
PORT_WWN
The world wide name of the remote device''s port.
char
23
NODE_WWN
The world wide name of the remote device
char
23
NAME
The name associated with the device
varchar
256
FC_ADDRESS
FC Address for the port in hex
varchar
6
FRAME_DATA_SIZE
The frame size, in bytes, of the device.
The default value is 512.
int
SPEED
Operating speed of the remote port.
int
STATE
Indicates whether the device is online or offline.
The default value is ‘Offline’.
varchar
64
SUPPORTED_COS
The types of classes that are supported on the
remote port; for example, Class-3
varchar
32
DEVICE_TYPE
The type of the device; for example, Disk or Tape.
varchar
64
BIND_TYPE
The persistent bind type. The default value is 0.
smallint
TARGET_ID
The identifier of the target device. The default value
is 0.
int
ROLE
The role of the device (target or initiator)
varchar
64
VENDOR
The vendor of the device
varchar
256
PRODUCT_ID
The device''s identifier.
varchar
256
PRODUCT_VERSION
Field which stores information regarging target rate
limiting on the remote port
varchar
256
QOS_PRIORITY
QOS Priority on the target. The default value is
'Unknown'.
varchar
64
QOS_FLOW_ID
QOS Flow ID on the target. The default value is 0.
varchar
64
CURRENT_SPEED
Current speed of the remote port, as enforced by
TRL.
The default value is 0.
varchar
64
TRL_ENFORCED
True if TRL(Target Rate limit) is enforced.
varchar
16
BUS_NO
Channel number in the PCI Bus. The default value is
0.
varchar
32
FCP_IM_STATE
Indicates whether the Fibre Channel Protocol Input
Method (FCP-IM) is online or offline.
varchar
128
IO_LATENCY_MIN
Minimum IO Latency value (< 79) in milliseconds and
is calculated when HBA port starts SCSI (FCP)
exchanges
varchar
32
IO_LATENCY_MAX
IO Latency value in milliseconds and is calculated
when HBA port starts SCSI (FCP) exchanges
varchar
32
IO_LATENCY_AVERAGE
Average IO Latency value in milliseconds and is
calculated when HBA port starts SCSI (FCP)
exchanges
varchar
32
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...