Brocade Network Advisor SAN User Manual
1073
53-1003154-01
SAN performance overview
28
3. Click Edit.
The AddFabric Discovery dialog box displays.
4. Select the Manual option to view SNMP credentials.
5. Click the SNMP tab.
6. Select v1 or v3 from the SNMP Version list.
7. Make sure SNMP credentials match those on the device.
8. Click OK on the AddFabric Discovery dialog box.
9. Click Close on the Discover Fabrics dialog box.
-
To set SNMP credentials in the Management application, refer to
“Discovery”
on page 35.
•
Make sure that the SNMP security level is set to the appropriate level for the switch.
-
To check the SNMP security level, use the snmpconfig --show secLevel command.
Example of checking SNMP security level
snmpconfig --show secLevel
GET security level = 0, SET level = 0
SNMP GET Security Level: No security
SNMP SET Security Level: No security
-
To set the SNMP security level, use the snmpconfig --set secLevel command.
Example of checking SNMP security level
snmpconfig --set secLevel 0
Select SNMP GET Security Level
(0 = No security, 1 = Authentication only, 2 = Authentication and Privacy,
3 = No Access): (0..3) [0]
•
To collect performance data for GE ports and FCIP statistics, make sure that SNMP v3
credentials match and that FCIP-MIB capability is enabled.
-
To check FCIP-MIB capability, use the snmpconfig --show mibcapability command.
Example of showing FCIP-MIB
FCRRouter:admin> snmpconfig --show mibcapability
FCIP-MIB: YES
-
To enable FCIP-MIB capability, use the snmpconfig --set mibcapability command.
Example of enabling FCIP-MIB
FCRRouter:admin> snmpconfig --set mibcapability
FA-MIB (yes, y, no, n): [yes]
FICON-MIB (yes, y, no, n): [yes]
HA-MIB (yes, y, no, n): [yes]
FCIP-MIB (yes, y, no, n): [yes]
ISCSI-MIB (yes, y, no, n): [yes]
•
To collect performance data on a Virtual Fabrics-enabled device, use the userconfig --show
command to make sure the Fabric OS user has access to all the Virtual Fabrics. Make sure that
the SNMPv3 user name is the same as the Fabric OS user name. Otherwise, the data is not
collected for virtual switches with a non-default Virtual Fabric ID. By default, the admin user
has access to all Virtual Fabrics.
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...