![Brocade Communications Systems Network Advisor 12.3.0 Скачать руководство пользователя страница 1394](http://html1.mh-extra.com/html/brocade-communications-systems/network-advisor-12-3-0/network-advisor-12-3-0_user-manual_28173231394.webp)
1342
Brocade Network Advisor SAN User Manual
53-1003154-01
MAPS monitoring categories
33
Resource monitoring category
The Resource category monitors the system RAM, flash, CPU, and memory.
The Resource category uses monitors to perform the following tasks:
•
Configure thresholds for MAPS event monitoring and reporting for the environment and
resource classes. Environment thresholds enable temperature monitoring, and resource
thresholds enable monitoring of flash memory.
•
Configure memory or CPU usage parameters on the switch or display memory or CPU usage.
Configuration options include setting usage thresholds which, if exceeded, trigger a set of
specified MAPS alerts. You can set up the system monitor to poll at certain intervals and
specify the number of retries required before MAPS takes action.
Table 116
lists measures in the Resource category and describes what each measure indicates.
FCIP monitoring category
The FCIP category enables you to define rules for Fibre Channel over IP (FCIP) health, including
circuit state changes and utilization as well as packet loss.
Table 117
lists measures in the FCIP category and describes what each measure indicates.
Telnet violations (SEC_TELNET)
Telnet violations that occur when a Telnet connection request reaches a
secure switch from an unauthorized IP address.
TS out of sync (SEC_TS)
Time Server (TS) violations that occur when an out-of-synchronization error
has been detected.
TABLE 116
Resource measures
Measure
Description
Temperature (TEMP)
Refers to the ambient temperature inside the switch, in degrees Celsius.
Temperature sensors monitor the switch in case the temperature rises to levels at
which damage to the switch might occur.
Flash (FLASH_USAGE)
Monitors the compact flash space available by calculating the percentage of flash
space consumed and comparing it with the configured high threshold value.
CPU
Monitors the CPU available by calculating the percentage of CPU consumed and
comparing it with the configured threshold value.
Memory (MEMORY_USAGE) Monitors the available memory by calculating the percentage of memory consumed
and comparing it with the configured threshold value.
TABLE 117
FCIP measures
Measure
Description
FCIP circuit state changes (CIR_STATE)
The state of the circuit has changed for one of the following reasons:
•
The circuit has gone offline.
•
The circuit has come online.
•
The circuit is faulty.
FCIP circuit utilization (CIR_UTIL)
The percentage of utilization for the circuit at the time of the last poll.
TABLE 115
Security measures (Continued)
Measure
Description
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...