808
Brocade Network Advisor SAN User Manual
53-1003154-01
High availability clusters
20
High availability clusters
A high availability (HA) cluster consists of exactly two encryption engines configured to host the
same CryptoTargets and to provide Active/Standby failover and failback capabilities in a single
fabric. One encryption engine can take over encryption and decryption tasks for the other
encryption engine if that member fails or becomes unreachable.
NOTE
High availability clusters between two encryption engines (EEs) should not be confused with High
Availability opaque mode that is supported in KMIP.
When creating a new HA cluster, add one engine to create the cluster, then add the second engine.
You can make multiple changes to the HA clusters list; the changes are not applied to the switch
until you click OK.
NOTE
An IP address is required for the management port for any cluster-related operations.
HA cluster configuration rules
The following rules apply when configuring an HA cluster:
•
The encryption engines that are part of an HA cluster must belong to the same encryption
group and be part of the same fabric.
•
An HA cluster cannot span fabrics and it cannot provide failover/failback capability within a
fabric transparent to host MPIO software.
•
HA cluster configuration and related operations must be performed on the group leader.
•
HA clusters of FS8-18 blades should not include blades in the same DCX Backbone chassis.
NOTE
In Fabric OS 6.3.0 and later, HA cluster creation is blocked when encryption engines belonging
to FS8-18 blades in the same DCX Backbone chassis are specified.
•
Cluster links must be configured before creating an HA cluster.
•
It is recommended that the HA cluster configuration be completed before you configure
storage devices for encryption.
•
It is mandatory that the two encryption engines in the HA cluster belong to two different nodes
for true redundancy. This is always true for switches, but is not true if two FS8-18 blades in the
same DCX Backbone chassis are configured in the same HA cluster.
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...