![Brocade Communications Systems Network Advisor 12.3.0 Скачать руководство пользователя страница 1113](http://html1.mh-extra.com/html/brocade-communications-systems/network-advisor-12-3-0/network-advisor-12-3-0_user-manual_28173231113.webp)
Brocade Network Advisor SAN User Manual
1061
53-1003154-01
FC troubleshooting
27
7. Click Close on the Diagnostic Port Test dialog box.
Configuring link traffic test parameters
You can conifigure these parameters to improve accuracy and to measure link performance on
stress conditions with more traffic.
1. Enter the number of frames to use in the traffic test in the Number of Frames field.
Minimum is 1 million (default). Maximum is 2,147,483,647 million.
2. Enter the duration you want the test to run in the Duration Hours and Minutes fields.
This option is mutually exclusive of frames option.
Minimum is 0 hours and 1 minute (default). Maximum is 99 hours and 59 minutes.
3. Enter the frame size you want for the traffic test in the Frame Size field.
Minimum is 36 bytes. Maximum is 2236 bytes. Default is 1024 bytes.
Distance between ports
Approximate distance between the ports is
numerical_value
meters.
Reverse Optical Loopback Test
Successfully completed Reverse Optical Loopback Test.
Reverse Optical Loopback Test failed.
Roundtrip link latency
Roundtrip link latency:
numerical_value
nano-seconds.
Buffers required
Buffers required:
numerical_value
Link Traffic Test Configuration
used
No. of test frames:
numerical_value
Million
Duration of test (HH:MM): hours:minutes
Test frame size:
numerical_value
Bytes
Payload Pattern:
pattern_name
or
frame_data
FEC (enabled/active): Yes/No
CR (enabled/active): Yes/No
Start time: day month date hour:minute:seconds year
End time: day month date hour:minute:seconds year
NOTE: If you do not set a payload pattern, results do not show payload
pattern.
If any test fails, that test displays
as failed and a Failure report
displays.
Sample failure report :
Errors detected (local): CRC, Bad_EOF, Enc_out
Errors detected (remote): CRC, Bad_EO
Run portstatsshow and porterrshow for more detail on the errors.
HBA Electrical test successful
Successfully completed Electrical Loopback Test on port
HBA_port_number
of the HBA
HBA_node
HBA Electrical test failed
Electrical Loopback Test failed on port
HBA_port_number
of the HBA
HBA_node
TABLE 80
Status Detail messages
Operation/Test
Possible message
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...