48
Brocade Network Advisor SAN User Manual
53-1003154-01
Troubleshooting fabric discovery
3
Virtual Fabric discovery troubleshooting
The following section state possible issues and the recommended solutions for Virtual Fabric
discovery errors.
Problem
Resolution
At the time of discovery, the seed switch is Virtual Fabric-enabled; however, the user does not have
Chassis Admin role for the seed switch.
At the time of discovery, the user does not have the Chassis Admin role for all other switches in the
fabric.
After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled;
however, the user does not have Chassis Admin role.
Make sure the user account has
Chassis Admin role on the Fabric OS
device.
At the time of discovery, the seed switch is Virtual Fabric-enabled; however, the user does not have
access to all possible logical switches (access to all possible Fabric IDs 1 - 128).
At the time of discovery, the user does not have access to all possible logical switches for all other
devices in the fabric.
After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled;
however, the user does not have access to all possible logical switches.
Make sure the user account has
access rights to all logical switches
(access to all possible Fabric IDs 1 -
128) on the Fabric OS device.
At the time of discovery, SNMP v3 is not configured.
At the time of discovery, SNMP v3 is not configured for all other switches in the fabric.
After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled;
however, SNMP v3 is not configured
Configure the SNMP v3 information
for the Virtual Fabric-enabled device.
At the time of discovery or fabric refresh, the SNMP v3 user account does not have the Chassis
Admin role.
Make sure the SNMP v3 user account
has the Chassis Admin role on the
Fabric OS device.
At the time of discovery or refresh, the SNMP v3 user account does not have access to all possible
logical switches (access to all possible Fabric IDs 1 - 128).
This access is required to obtain performance statistics from all logical switches.
Make sure the SNMP v3 user account
has access rights to all logical
switches (access to all possible Fabric
IDs 1 - 128) on the Fabric OS device.
At the time of discovery or fabric refresh, the SNMP v3 user account does not have a matching
Fabric OS switch user account.
This is required to obtain performance statistics from all logical switches.
Make sure the SNMP v3 user account
is also defined as a Fabric OS switch
user.
At the time of fabric refresh, the physical chassis is reachable; however, a previously discovered
logical switch is not reachable.
The logical switch has been deleted
or the Fabric ID was changed.
To find a logical switch, right-click the
physical chassis within the Chassis
Group in the Product List and select
Logical Switches.
All logical switches on the selected
physical chassis display in a list.
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...