27
IP Performance sends dummy data as fast as possible to the remote IP address and measures
how much data can be sent over a given interval. IP Performance attempts to saturate the
network link to see how much bandwidth is available. It will display the media link bandwidth
only if no other traffic is flowing. The remote IP address must belong to a managed switch so
that IP Performance can set up the receiving end on the remote switch.
For more information about IP Performance, refer to Chapter 20 in the
Fabric OS
Administrator’s Guide
.
During the IP Performance test, data is sent continuously and statistics are sampled every 30
seconds. At the end of the period, the IP Performance results dialog box displays. The IP
Performance results dialog contains a table with one row for each 30-second sample of the
test. Columns in the perf results dialog are:
7. Click Close on the IP Performance Result dialog box.
8. Click Cancel on the IP Performance dialog box.
Field/Component
Description
Available Bandwidth
The average bytes per second sent during the sample interval. This is a count of FC
payload bytes; for example, the throughput seen by an FC application. It is slightly
lower than the actual bytes-per-second on the wire since it does not include
headers and acknowledgements.
Weighted Bandwidth
The weighted bandwidth represents what the FCIP tunnel / FC application sees for
throughput rather than the Ethernet on-the-wire bytes.
Loss Percent
An estimate of the percentage of data packets lost during the sampling interval,
based on TCP re-transmits.
DELAY
The average round trip time to send a packet of data and receive the
acknowledgement.
PMTU
(Path Maximum
Transmission Unit)
The largest packet size that can be transmitted over the end path without
fragmentation. This value is measured in bytes and includes the IP header and
payload. IP Performance tries the configured Fabric OS Jumbo MTU value (anything
over 15000, then 1500, then 1260. The value displayed in the table is the largest
value that worked.
Содержание Network Advisor 12.3.0
Страница 1: ...53 1003154 01 11 July 2014 Brocade Network Advisor SAN User Manual Supporting Network Advisor 12 3 0...
Страница 4: ...iv Brocade Network Advisor SAN User Manual 53 1003154 01...
Страница 86: ...34 Brocade Network Advisor SAN User Manual 53 1003154 01 Uninstalling a patch 2...
Страница 190: ...138 Brocade Network Advisor SAN User Manual 53 1003154 01 Fabric tracking 4...
Страница 216: ...164 Brocade Network Advisor SAN User Manual 53 1003154 01 User profiles 5...
Страница 462: ...410 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching for an assigned event filter 9...
Страница 478: ...426 Brocade Network Advisor SAN User Manual 53 1003154 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 612: ...560 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting Host port mapping 13...
Страница 620: ...568 Brocade Network Advisor SAN User Manual 53 1003154 01 Exporting storage port mapping 14...
Страница 720: ...668 Brocade Network Advisor SAN User Manual 53 1003154 01 Security configuration deployment 17...
Страница 744: ...692 Brocade Network Advisor SAN User Manual 53 1003154 01 Configuring Virtual Fabrics 19...
Страница 1036: ...984 Brocade Network Advisor SAN User Manual 53 1003154 01 Troubleshooting FCIP Ethernet connections 22...
Страница 1068: ...1016 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing thresholds 24...
Страница 1098: ...1046 Brocade Network Advisor SAN User Manual 53 1003154 01 Swapping blades 25...
Страница 1104: ...1052 Brocade Network Advisor SAN User Manual 53 1003154 01 Searching the configuration snapshots 26...
Страница 1176: ...1124 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN connection utilization 28...
Страница 1282: ...1230 Brocade Network Advisor SAN User Manual 53 1003154 01 Removing a frame monitor from a switch 30...
Страница 1306: ...1254 Brocade Network Advisor SAN User Manual 53 1003154 01 Viewing historical reports for a configuration policy manager 31...
Страница 1378: ...1326 Brocade Network Advisor SAN User Manual 53 1003154 01 Event logs 32...
Страница 1432: ...1380 Brocade Network Advisor SAN User Manual 53 1003154 01 MAPS integration with other features 33...
Страница 1448: ...1396 Brocade Network Advisor SAN User Manual 53 1003154 01 Upload failure data capture 34...
Страница 1490: ...1438 Brocade Network Advisor SAN User Manual 53 1003154 01 SAN shortcut menus A...
Страница 1494: ...1442 Brocade Network Advisor SAN User Manual 53 1003154 01 Call Home Event Tables B...
Страница 1524: ...1472 Brocade Network Advisor SAN User Manual 53 1003154 01 About Roles and Access Levels D...
Страница 1552: ...1500 Brocade Network Advisor SAN User Manual 53 1003154 01 Regular Expressions F...
Страница 1920: ...1868 Brocade Network Advisor SAN User Manual 53 1003154 01 Views H...