Page 61
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
Ensure that the flow rate, batch amount and relay timer are set up so that the relay will
de-energize before the end of each batch. Should the relay still be energized when the
end of a batch is detected, then the time at which the relay will de-energize will be
extended to the
Relay Timer
time from the new batch ending. If this repeats, the relay
could remain continuously energized.
If the
STOP
soft button is pressed:
!
The relay channel Status: is indicated
as
PAUSED.
!
If the relay is energized, it will
immediately de-energize.
!
The
RESUM
(resume) soft button
appears, replacing the
STOP
soft
button.
!
The flowmeter will no longer advance
Total this Batch:
nor energize the relay
and increment
Current Batch #:
as
batches of fluid pass by in the pipe.
!
Total all Batches:
continues to advance
if there is flow in the pipe.
If the
RESUM
soft button is pressed:
!
The relay channel Status: returns to
ACTIVE.
!
The
RESUM
soft button is replaced by the
STOP
soft button.
!
The
Total this Batch:
value clears to zero.
!
The
Current Batch #:
value increases by one, indicating a new batch in progress.
!
Operation is as before
STOP
was pressed (
Total this Batch:
advances and, at the
end of each batch, clears, energizing the relay for a specified time and advancing
Current Batch #:
).
To start counting batches from zero again or clear the value of
Total all Batches:
, use the
and
and
CLEAR
soft buttons.
The
Current Batch #
,
Total this Batch
and
Total all Batches
values can be cleared.
To do this, press the and soft buttons until the desired value is
highlighted. The
CLEAR
soft button then appears in the left-most position. Pressing this
soft button zeros the value.
The clearing of counts and totals can be blocked by configuring the
Total Display
Function
to
Clear Total Disabled
. If this is done, the
CLEAR
soft button does not
appear. Note that this configuration item is in the
Metering Setup
branch, but even so
affects
Process Control
functions.
If the relay channel is configured for
Batch Start
type
MANUAL
, the
Batch Amount:
value can be changed. To do this, press the and soft buttons until
the present value is highlighted. The
EDIT
soft button then appears in the left-most
position. Pressing this soft button allows the value to be edited.
It is not possible to change the
Batch Start:
type or the
Relay Timer:
value. It is also not
possible to change the
Batch Amount:
value if the
Batch Start
type is
AUTO.
Ç
È
Ç
È
Ç
È
8.2.3
Batch
Clear
8.2.4
Batch
Edit