higher accuracy and a more stable display but a slower response to changes in flow rate.
The Flow total value is not affected by flow rate averaging setting.
Display --> Display Update
allows
to select the time interval between the
presentation of new flow information to the display, signal outputs, process control,
logging, etc. The choices offered are 0.25, 0.50, 1.00, 2.50 and 5.00 seconds. Both flow rate
and flow total are affected.
Display --> Low Flow Cutoff
allows
to specify a flow rate below which the actual
measured value is replaced by zero. When factory configured, a flow rate equal to
approximately .25 feet per second is set.
Display --> High Flow Cutoff
allows
to specify a high rate above which the actual
measured value is replaced by the cutoff value.
Display --> Scaling Offset
allows
to specify a scaling factor, which would generally
be close to one, by which measured flow is multiplied. If required, this value can be used
to quickly adjust for errors in the flow rate reading after a field calibration has been
performed.
you
you
you
you
Signal Output --> Analog Output
allows you
Display --> Display Language
allows
to
select the natural language of display text.
The choices offered are English, Spanish,
German and French.
Display --> Flow Rate Averaging
allows
to select the time interval over which flow
rate measurements are averaged before
presentation to the display, signal outputs,
process control, logging, etc. The choices
offered are 0.25, 0.50, 1.00, 2.50, 5.00 and
10.00 seconds. Longer values result in
you
you
6.3.3
Metering
Setup
(continued)
ENTER
Ç
ESC
È
Configuration Set #3
Ê
Metering Setup
Display Language
Low Flow Cutoff
Display Update
Flow Rate Averaging
Display
Ê
High Flow Cutoff