Page 38
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
On selecting this action, a list of valid
Configuration Sets
will be shown. The user can
select a Configuration Set using the and soft buttons and press the
ENTER soft button to activate that Set.
6.2.2.1
Activate a
Configuration
Set
Ç
È
ENTER
ENTER
Ç
ESC
È
Setup Root Menu
Manage Configuration Sets
Activate a Configuration Set
Configuration Set #1
Ê
Configuration Set #3
Configuration Set #4
Ê
The figure at right shows the selection of Set
#3 where only sets #1, #3 and #4 are valid
(Sets #2 and #5 have either been deleted or
nothing has ever been saved to them). If
there is a password associated with the
chosen Set, you will be prompted to supply it
(see figure in section 6.2.1.2 below).
The flowmeter then exits the
Setup Mode
to the
Transducer Positioning State
and
eventually the
Startup State
and then to
the
Run Mode
where it will perform flow measurement using the configuration data of
that
Set
.
The
Setup Root Menu
will return to the screen without the activation of a
Configuration Set
if the user fails to supply a required password, or presses the
ESC
soft button twice.
Only saved, numbered
Configuration Sets
can be activated. Neither the
Factory
Configuration
nor the
Working Set
can be activated without first being saved to a
numbered Set.
This action is similar to
Activate a Saved Configuration Set
in that the user is able to
select and open a valid
Configuration Set
. On pressing the
ENTER
soft button and
supplying a password if necessary, the selected
Configuration Set
will be loaded into
the
Working Set
and the
Configuration Edit Menu
will appear. The banner will read
Configuration Set #N
, where N is the number of the selected
Set
. From this screen,
the user can navigate to and edit configuration items. For details, see section 6.3 below.
On selecting this action, the pre-set
Factory Configuration
will be loaded into the
Working Set
and the
Configuration Edit Menu
will appear. The banner will read
New Configuration Set
. From this screen, you can navigate to and edit configuration
items and save the configuration to a numbered Set. For details, see section 6.3 below.
Deleting a
Configuration Set
starts out the same as
Activate a Saved
Configuration Set
. On pressing the
ENTER
soft button and supplying a password if
necessary, the
Configuration Set
will be invalidated. It will no longer appear as a
choice to be activated or opened for editing (until new configuration information is saved
to that numbered Set). If all
Configuration Sets
are deleted, the flowmeter will operate
according to the
Factory Configuration
.
6.2.2.2
Open a
Configuration
Set
6.2.2.3
Create a New
Configuration
Set
6.2.2.4
Delete a
Configuration
Set