1) Enter all the appropriate information for pipe material and dimensions.
2) Enter a custom speed of sound for the fluid in meters/second. Use a best first guess –
if it's a water based fluid, start with something close to the speed of sound for water.
If it's an oil based fluid, use something close to the speed of sound for oil.
3) Save and activate your configuration.
4) Place transducers at the spacing specified by the meter. The meter will now calculate
and display a speed of sound in the upper right hand corner If the displayed speed of
sound matches that which was entered, then that figure is what should be used. If
the displayed speed of sound is different, go back to the configuration (step #2 above)
and change the custom fluid speed of sound to the displayed value.
4) Save and activate the configuration.
5) Place the transducers at the newly specified location.
The displayed speed of sound should match the entered speed of sound (provided proper
transducer placement and no change in temperature of the fluid).