Page 21
Sonic-Pro
Industries, Ltd.
Industries, Ltd.
ProSeries
by Blue-White Ind.
TM
The Sonic-Pro SPU wiring compartment is equipped with:
six large liquid-tight cable gland connectors,
two small
2 each for the transducer cables
3 each for the process control relay connection cables
The
blank grommet plug
should be used when the
liquid-tight cable gland connectors, and
a communications cable liquid-tight cable gland grommet and plug.
To ensure that the SPU enclosure remains water-tight, the following cable glands should
be used:
The
six large liquid-tight connectors
can be used with any cable diameter from .200
to .394 inches (5.1 to 10.0 mm). They are provided for:
1 each for the power input cable
The
two small liquid-tight connectors
can be used with any cable diameter from .118
to .255 inches (3.0 to 6.5 mm). They are provided for:
1 each for the 4-20 mA output signal cable
1 each for the pulse output signal cable
The
communications cable grommet
can be used with any cable diameter from .190
to .205 inches. It is provided for any one of the following cable types:
USB cable
Ethernet Cable
RS-232 serial cable
RS-485 serial cable
communications cable grommet is
not required.
3.8
Cable Gland
Liquid-Tight
Connections
4.99k
5-30 VDC
Current output
(0-1000 Hz)
Current
input
Current
output
4-20mA receiver
Sonic-Pro Meter
Frequency output
(4-20 mA)
Digital Pulse Receiver
Sonic-Pro Meter
Frequency
input
Ground
1
2
3
4
5
Signal Output
Terminal Block
SIGNAL OUTPUT CONNECTIONS
Neutral
input
Line
intput
95 to 264 VAC 50/60Hz
30 WATTS MAX
15 to 30 VDC
30 WATTS MAX
Sonic-Pro Meter
Positive
(+)
Negative
(-)
1
2
3
4
5
Power Input
Terminal Block