- 67 -
7. Trouble Shooting
Error that occurred in using this controller BIS C-489 and trouble shooting is explained in this chapter.
(
)
7.1 List of Error Code
Errors that occurred in using this controller BIS C-489 , error, processing procedure are indicated below.
(
)
The newest error code is stored in the stored area for executing result.
The following digits are stored in ** of error code.
・
・・・・・・・00H
・CM・・・・・・・・・・・05H
・SW・・・・・・・・・・・0EH
all instructions
・RD・・・・・・・・・・・01H
・CL,FI・・・・・・・・06H
・LR・・・・・・・・・・・20H
・WD・・・・・・・・・・・02H
・CR・・・・・・・・・・・0BH
・AR・・・・・・・・・・・03H
・CW・・・・・・・・・・・0CH
・AW・・・・・・・・・・・04H
・SR・・・・・・・・・・・0DH
Error name
Error contents
LED
Processing procedure
Error code
Hex.
Number of
Number of specified address
Check "number of a word" are not
*1
**01H
(
)
executing word
+ word exceed 160 words.*1
exceed the last address 160
error
Block setting
Block no. setting switch
Check block no. setting switch does not
switch error
exceeds setting range.
exceed setting range.
**03H
Set address
Setting address exceeds
Check "address" (page address in WP
error
setting range.
page address
instruction) of sequence program does not
**11H
(
digit in WP instruction
exceed setting range of address.
)
Number of
Setting word digit exceeds
Check "word digit" (setting / cancel digit in WP
setting word
setting range. setting / cancel
instruction) of sequence program does not
**12H
(
error
digit in WP instruction
exceed setting range of word digit.
)
Code tag
Code tag is unpresent in
Put code tag into communication area.
unpresent error
communication area.
ID-ERR.
Check wiring of read/write head.
**13H
R/W head cable breakage.
Code tag
Error occurs while
Check communication distance of code tag
communication
communicating with code tag
and center off-set.
**14H
error
Write protection
Executed writing to write
Check "address" and "a
error
protection area.
communication word digit" are not in write
**16H
protection area.
Instruction code
Set instruction code that
Check instruction code.
error
is not defined.
**22H
*1 depends on memory capacity of code tag