- 12 -
3.3.2 Details of Remote Resistor
(1) Specifying area for instruction code
Specifies instruction to code tag.
[ex.] Specifying reading instruction (RD) (in using 2 channels)
Replaces upper byte and lower byte, and converts it to ASCII code then stores the code.
4452H
Initial digit :
R
D Instruction code
Replaces upper byte
and lower byte
D
R
ASCII code
4
4
5
2
Specify ASCII code directly
①
Specify 4452H(RD)
TOP
Hn
H4452
K1
○
Store into specifying area for instruction code
Head I/O number of master unit
Change with ASC instruction
②
Store 4452H
ASC
RD
D0
TOP
Hn
D0
K1
○
Store into specifying area for instruction code
Head I/O number of master unit
Specifying area for the first address
(2)
Specify the first address of code tag memory to read or write data.
: 0 ... 4095 (0H ... FFFH)
Specifying range
: 0
Initial digit
[ex.] Specify address 120
First address
TOP
Hn
K120
K1
○
Store into specifying area for first address
Head I/O number of master unit
<Attention>
Specify in the following range.
First a Processing numbers =< 4096 (1000H)
・
Specify in the range of memory capacity of the code tag.