- 39 -
(C) In using QCPU (Q mode)
Automatic refresh parameter and initial setting are set with GX Developer as followings.
* Regard that the following example shows refresh range RX : M208...M335, RY : M336...M463
1. Setting with GX Developer
<
>
Automatic refresh parameter
Start I/O No.
: 0000
・
Operation setting
: -
・
Type
: Master station
・
Master station data link type
: PLC parameter auto start
・
Mode setting
: Online (Remote net mode)
・
All connect count
: 1
・
Remote input (RX) refresh device
: M208
・
Remote output (RY) refresh device
: M336
・
Remote register (RWr) refresh device
: D200
・
Remote register (RWw) refresh device
: D100
・
Special relay (SB) refresh device
: SB0
・
Special register (SW) refresh device
: SW0
・
Retry count
: 3
・
Automatic reconection station count
: 1
・
Standby master station number
: 0
・
PLC down select
: Stop
・
Scan mode setting
: Asynchronous
・
Delay information setting
: 0
・
Station information setting
: Station information
・
Initial setting of remote device
: Initial setting
・
Interrupt setting
: -
・
<Initial setting>
Input format
Hex.
Execute
Operating
Condition of executing procedure
Contents of executing
flag
condition
Condition
Device
executing
Writing
Device
Writing
device
number
condition
device
number
data
Factory setting
Execute
Set new
RX
78
ON
RY
00
ON
Execute
Same as prev. set
RX
78
ON
RY
78
ON
Execute
Same as prev. set
RX
78
ON
RY
79
ON
Execute
Set new
RX
78
OFF
RY
78
OFF
Execute
Set new
RX
79
ON
RY
79
OFF
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
Execute
Set new
2. Program
SM400
FROM
H0
H680 K4M100
K4
Reading other data link condition
M328
M100
SET
SB0D
Specify registering of initial procedure
(RX78) (link)
M213
FROMP
H0
H2E1 R0
K1
Reading error code of setting dip switch
SB5F
(RX5)
RST
SB0D
OFF registering of initial procedure