- 62 -
6.11 Stop Command of Sequence Instruction
Stop command of the sequence instruction stops the sequence instruction (AR,SR,AW,SW)
Example of programming
The example is programmed on the following condition.
(
)
Program to stop sequence instructions that is written in this chapter.
Using channel ................................................ CH1
External External
Signal
interlock signal
Start
SET
M2
SM400
Reading other data link condition
FROM
H0
H680
K4M100
K4
M2
M100
M331
M212
M213
M340
M1
sequence instruction
RST
M340
Stop
(link) (RX7B)
(RX4)
(RX5) (RY4)
(RY4)
Finish sequence instruction
RST
M1
M211
Finish instruction
RST
M2
(RX3)
M213
(RX5)
<Attention>
Reset instruction after timer counting in the case of stop command of sequence instruction
is executed while the timer of executing interval of sequence instruction is operating.