- 13 -
(3) Specifying area for processing number
Specify processing number of data to be read or written.
: 1 ... 512(1H ... 200H)
Specifying range
: 1
Initial digit
[ex.] Specify processing number to be 32
(
)
Processing number read/write
TOP
Hn
K32
K1
○
Store into specifying area for processing number
Head I/O number of master unit
<Attention>
Specify in the following range.
First a Processing numbers =< 4096 (1000H)
・
Specify in the range of memory capacity of the code tag.
(4) Specifying area for writing data
Specify data to be written into code tag.
[ex.] Specify contents of D100...D104 to writing data (selected 2 channels).
First address of writing data
TOP
Hn
D100
K5
○
Store into specifying area for writing data
Head I/O number of master unit
(5) Storing area for instruction code result
Stores instruction code that executed to processor BIS C-489 .
(
)
(6) Storing area for executing result
Stores error code.
(7) Storing area for reading data
Stores reading data from code tag.