- 10 -
(2) Remote output (RY)
Device No.
CH1
CH2
Signals
Contents
RYn0
Selecting initial
Specify processing unit or number of channel to use with "user
setting
setting" or "factory setting". By selecting "user setting", processing
unit, number of using channel could be selected by user.
OFF : User setting
ON : Factory setting
(Setting contents : word unit, both of CH1,CH2 are used)
RYn1
Selecting
Specify processing unit of processing data. Setting is effective
processing
when select initial setting (RYn0) is OFF (user setting).
unit
It is only word unit setting.
OFF : word unit
ON : unused (to set ON, it will be word unit.)
RYn2
Selecting number
Specify number of channel to use. Setting is effective when
of channel
selecting initial setting (RYn0) is OFF (user setting).
OFF : both of CH1,CH2 are used
ON : only CH1 is used
RYn4
RYnC
Require executing Executes instruction when require executing identification
ID instruction
instruction is ON.
RYn5
RYnD
Unused
Unused
RYn6
RYnE
Unused
Unused
RYn7
RYnF
Finish divided data
Refer to RXn7, RXnF.
RY(n+1)0
Unused
Unused
...
RY(n+6)F
RY(n+7)8
Flag for finishing to
Refer to RX(n+7)8, RX(n+7)9.
process initial data
RY(n+7)9
Flag for requiring to
set initial data