- 37 -
(5) Writing to remote output (RY)
Create the following program and write M328...M455(M336...M463) to RYn0...RY(n+7)F.
M9036(SM400)
TO
H0
H160 K4M328
K8
Write M328...M455 to RYn0...RY(n+7)F
(K4M336)
(M336...M463)
* Example of sequence program for ACPU. Digits for QCPU Q mode , QnACPU are indicated in
.
(
)
( )
<Attention>
Delete the sequence program in chart above, in the case of the following setting is set .
*Using QJ61BT11,AJ61QBT11,A1SJ61QBT11
Set automatic refresh parameter with GX Developer
*Using AJ61BT11,A1SJ61BT11
Set automatic refresh with instruction for CC-Link
6.5.1 Processing program when fault condition occurred
Reference the chart below to create a program for fault conditions.
Initial setting program of master unit
(
)
parameter setting, data link setting
M9036(SM400)
FROM H0 H680 K4M100 K4
Reading data link condition
FROM H0 H0E0 K4M200 K8
Reading RX information
(K4M208)
M100
RST M332(RY4)
Create processing program
(M340)
as refer to left chapter.
M332 (M340) :
RST M1
Relay of request of
identification instruction
M1:
Processing program
External relay of request of
identification instruction
Identification communication instruction program
M9036(SM400)
TO H0 H160 K4M328 K8
Writing RY information
(K4M336)
* Example of sequence program for ACPU. Digits for QCPU (Q mode), QnACPU are indicated in ( ).
<
>
Attention
Reset request of identification instruction to avoid unexpected communication in program when
fault is occurred.
The instruction is executed again after recovery of link in the case of external contact M1 for
(
)
starting identification instruction is not reset.
Содержание BIS C-489-1 KBT02 Series