- 32 -
6.2 List of Instructions and Commands
The following instructions and commands can be executed with the processor BIS C-489 .
(
)
Instructions/
Instruction code
Process
Reference
Functions
Commands
ASCII
Hex.
Reading
RD
4452H
Reads data from code tag.
6.7.1
Reading
CR
5243H
Compares data to check.
Sequence
AR
5241H
Executes reading in sequence until code tag gets into
6.7.2
Reading
SR
5253H
communication area, and executes reading when code tag got
into communication
After that, compares data to check.
Writing
WD
4457H
Writes data to code tag.
6.8.1
Writing
CW
5743H
Compares data to check.
Sequence
AW
5741H
Executes writing in sequence until code tag gets into
6.8.2
Writing
SW
5753H
communication area, and executes writing when code tag got
into communication
After that, compares data to check.
Batch
FI
4946H
Writes specified data to specified area in code tag
6.8.3
writing
simultaneously.
Check
Comparing
CM
4D43H
Compares data of processor with data in code tag.
6.9
Clearance
Clearing
CL
4C43H
Clears specified area in code tag with "0"
6.10
Command
Sequence
Cancels sequence instruction compulsively.
6.11
instruction
Cancellation
Error
Executes error cancelling process.
6.12
cancellation
Clearing error LED, resetting error detected signal,
(
)
Clearing executing result store area in remote resister
Life
Reading
Reads life "expectancy information" of code tag that written in
expectancy
life
LR
524CH
code tag.
6.13
expectancy
of code tag
Содержание BIS C-489-1 KBT02 Series