- 28 -
5.4 Interlock
Matching of the input-output signals are dependent on instructions in the following table.
Set interlock to match input output signal dependent on instruction.
RXn3/RXnB ........... ID-BUSY
RXn4/RXnC ........... Finish ID instruction
RXn5/RXnD ........... Error detection
RX(n+7)8 ............... Flag for requiring to process initial data
RX(n+7)B ............... Remote READY
RYn4/RYnC ............ Require executing identification instruction
RYn5/RYnD ............. Require executing special instruction
... Signal for CH2
Codes
Input-output signal (Interlock signal)
Instructions
ASCII
Hex.
RXn3
RXn4
RXn5
RYn4
RYn5
RXnB
RXnC
RXnD
RX(n+7)8
RX(n+7)B
RYnC RYnD
Reading
RD
4452H
CR
5243H
Sequence reading
AR
5241H
SR
5253H
Writing
WD
4457H
Comparison writing
CW
5743H
×
×
×
○
○
○
○
Sequence reading
AW
5741H
Sequence
SW
5753H
Comparison writing
Batch writing
FI
4946H
Comparison
CM
4D43H
Clear
CL
4C43H
Reading life
LR
524CH
expectancy of code tag
――
――
×
○
○
×
×
○
×
Specifying stop
sequence instruction
――
――
×
×
○
Specifying error cancel
Specifying interval for
――
――
executing sequence
instruction
――
――
×
×
×
○
×
×
×
Specifying retry count
――
――
Specifying processing
unit
Specifying inzone
――
――
detection time
――
――
Select channel number
Interlock is required.
○・・・
Interlock is not required.
×・・・
Содержание BIS C-489-1 KBT02 Series