- 41 -
(b) In using QnACPU
Automatic refresh parameter is set with GX Developer as followings.
* Regard that the following example shows refresh range RX : M208...M335, RY : M336...M463
1. Setting with GX Developer
Start I/O No.
: 0000
・
Type
: Master station
・
All connect count
: 1
・
Remote input (RX)
: M208
・
Remote output (RY)
: M336
・
Remote register (RWr)
: D200
・
Remote register (RWw)
: D100
・
・
-
Special relay (SB)
:
Special register (SW)
: -
・
Retry count
: 3
・
Automatic reconnection station count
: 1
・
Standby master station number
: 0
・
PLC down select
: Stop
・
Scan mode setting
: Asynchronous
・
Delay information setting
: 0
・
Station information setting
: Station information
・
2. Program
SM400
FROM
H0
H680 K4M100
K4
Reading other data link condition
M328
M100
RST
M336
User setting
(RX78) (link)
(RY0)
RST
M337
Setting processing unit to word
(RY1)
RST
M338
Select number of using channel to 2 channel
(RY2)
MOVP K5
D100
Specify retry count (5 times)
MOVP K200
D101
Specify inzone detecting time
(2 sec.)
CH1
MOVP K50
D102
Specify interval for executing
sequence instruction (5 sec.)
MOVP K5
D108
Specify retry count (5 times)
MOVP K200
D109
Specify inzone detecting time
(2 sec.)
CH2
MOVP K50
D110
Specify interval for executing
sequence instruction (5 sec.)
SET
M456
ON finish processing initial data
(RY78)
SET
M457
ON require setting initial data
M213
(RY79)
FROMP
H0
H2E1 R0
K1
Reading error code of setting dip switch
M328(RX78)
(RX5)
RST
M456
OFF finish processing initial data
M329(RX79)
(RY78)
RST
M457
OFF require setting initial data
(RY79)