Operator’s Manual 25
If the wear strips are not the cause of the large gear rack clearance then shimming the
rack out to the gear will be a final fix. Space rack out from vertical plunger to achieve
desired dimension.
-
Shim 1-M-0146 is 14 ga (0.074 inch) (1.88 mm)
-
Shim 1-M-0147 is 20 ga (0.0375 inch) (0.95 mm)
-
These shims allow you to loosen the rack bolts and slide them in from the side.
How to put the vertical plunger “in time” if is “out of time.”
-
Put the vertical plunger in top position. (Cylinder extended)
-
Count the teeth on rack down to where the teeth on gear mesh with rack, and
then count teeth on other rack to corresponding teeth on gear. Both sides should
be the same for proper “timing.”