Service display
The remote control related messages:
Left / right joystick x / y / z-axis input signal too high / low
Calibrate the remote control again. If the problem does not
disappear, the remote control is damaged.
Error in left / right joystick x / y / z-axis parameters
Wrong setting on parameters. Check the parameter values.
Remote controller calibrated
Calibration is successful.
Remote controller calibration saved
Error in potentiometer parameters
Wrong setting on parameters. Check the parameter values.
Potentiometer input signal too high / low
Calibrate the remote control again. If the problem does not
disappear, the remote control is damaged.
No connection to the remote control
Connect the remote control to the machine by pushing the
green button on the control box, or plug in the control cable.
Electric system related messages:
Incorrect sensor supply voltage (5V) / (12V)
The sensor or cable is damaged.
Short circuit in motor starter main contactor output
The motor starter main contactor or cable is damaged. Contact
service.
Voltage without control in motor starter main contactor output
The motor starter main contactor or cable is damaged and
short circuit to voltage. Contact service.
Short circuit in motor starter output 2 / 3
The motor starter main contactor or cable is damaged. Contact
service.
Voltage without control in motor starter output 2/ 3
The motor starter main contactor or cable is damaged and
short circuit to voltage. Contact service.
Short circuit in dump valve output
The dump valve or cable is damaged or valve is in short circuit
to earth potential.
Main voltage phase missing or fuse blown
Phase inverter is on wrong position or power current plug is
blown.
Over temperature in motor starter contactor
Over heat relay has gone off. The relay should be recovered
within 5 minutes.
Short circuit in power on indicator lamp output
The indicator lamp or cable is damaged, or the lamp is in short
circuit to earth potential.
Voltage without control or broken circuit in power on
indicator lamp output
Voltage without control on indicator lamp or module output.
The indicator lamp or cable is damaged, or the lamp is in short
circuit to earth potential.
Short circuit in pressure reduce valve output
Short circuit in valve connector, cable or module output. The
valve or cable is damaged, or the lamp is in short circuit to earth
potential.
Voltage without control or broken circuit in pressure re-
duce valve output
Voltage without control on the valve or module output. The
valve or cable is damaged, or the lamp is in short circuit to volt-
age.
Содержание Robot 185
Страница 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Страница 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Страница 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Страница 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Страница 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Страница 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Страница 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Страница 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...