39
Robot 185
Service
Checking the extension cord
• Turn off the motor and unplug both ends of the extension cord.
• Check for external damages on the leads.
• Remove the protective shell of the plugs.
• Check that the leads are attached properly.
• Measure with an ohmmeter or with an equivalent device,
whether there is a break in the lead.
• Measure with an ohmmeter, whether there is a break between
the plug and the socket outlet.
• Check with the meter, if there is a short circuit between the
leads.
• Check that the leads are properly attached; that no gaping contact can occur.
• Reinstall the protective shell.
To be noted:
• The black and brown leads may have been installed in a different order than presented
in the figure. The lead installed into the R1 connector (1) of a contact must also be
installed to the same connector in the other connector.
• Only a competent professional is authorised to carry out service inspections on heavy
currents.
• The yellow/green lead must always be connected to the ground (2).
• The earth wire must be longer than the other leads, so that it is the last one to come off
if the cable is torn from the contact.
• If the earth wire is wrongly connected, it may cause a deadly electric shock.
Содержание Robot 185
Страница 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Страница 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Страница 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Страница 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Страница 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Страница 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Страница 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Страница 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...