38
Robot 185
Service
Electric system
General
Remember to check the condition of all electric wires on regular basis.
Only an authorized electrician is allowed to perform heavy current electricity service operations.
The electric cabinet does not usually need to be opened. Only an authorized electrician is allowed to do that.
Faulty cables may cause a malfunction in the machine functions and make the machine parts conductive.
Always remember that the electrical cable must be unplugged, before a conductive part can be removed.
Standard values for the fuse size and the extension cord (50 Hz)
Note! The electric conductor can be dimensioned only by an authorized professional and the dimensions
must follow the national and local regulations. The supply connection of the machine must be dimensioned
to the same current as to that of the plug and extension cord of the machine.
Rated
voltage
Minimum
voltage
Cross-sectional
area of the cable
Starting
current
Engine
power
Regulation for thermal
overload relay
Cable maximum
length
V
V
mm²
A
kW
A
m
380
361,0
6
90
18,5
41,7
169,0
380
361,0
10
90
18,5
41,7
281,7
380
361,0
16
90
18,5
41,7
450,7
400
380,0
6
90
18,5
39,6
187,3
400
380,0
10
90
18,5
39,6
312,1
400
380,0
16
90
18,5
39,6
499,4
415
394,3
6
90
18,5
38,2
201,6
415
394,3
10
90
18,5
38,2
336,0
440
418,0
6
90
18,5
36,0
226,6
440
418,0
10
90
18,5
36,0
377,7
460
437,0
6
90
18,5
34,4
247,7
460
437,0
10
90
18,5
34,4
412,8
480
456,0
6
90
18,5
33,0
269,7
480
456,0
10
90
18,5
33,0
449,4
500
475,0
4
90
18,5
31,7
195,1
500
475,0
6
90
18,5
31,7
292,6
550
522,5
4
90
18,5
28,8
236,0
550
522,5
6
90
18,5
28,8
354,0
575
546,3
4
90
18,5
27,5
258,0
575
546,3
6
90
18,5
27,5
387,0
Содержание Robot 185
Страница 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Страница 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Страница 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Страница 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Страница 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Страница 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Страница 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Страница 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...