63
Robot 185
Service display
Short circuit in tower turn output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in rear boom output
Broken circuit in rear boom control valve or cable. The valve or
cable is damaged.
Error in rear boom parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in rear boom feedback input
Feedback without control in rear boom feedback input. Mal-
function on wires or wiring. Possible short circuit to voltage.
Contact service.
Short circuit in rear boom output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in main boom output
Broken circuit in main boom control valve or cable. The valve
or cable is damaged.
Error in main boom parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in main boom feedback input
Feedback without control in main boom feedback input. Mal-
function on wires or wiring. Possible short circuit to voltage.
Contact service.
Short circuit in main boom output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in dipper boom output
Broken circuit in dipper boom control valve or cable. The valve
or cable is damaged.
Error in dipper boom parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in dipper boom feedback input
Feedback without control in dipper boom feedback input.
Malfunction on wires or wiring. Possible short circuit to voltage.
Contact service.
Short circuit in dipper boom output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in tele boom output
Broken circuit in tele boom control valve or cable. The valve or
cable is damaged.
Error in tele boom parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in tele boom feedback input
Feedback without control in tele boom feedback input. Mal-
function on wires or wiring. Possible short circuit to voltage.
Contact service.
Short circuit in tele boom output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in tool output
Broken circuit in tool control valve or cable. The valve or cable
is damaged.
Error in tool parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in tool feedback input
Feedback without control in tool feedback input. Malfunction
on wires or wiring. Possible short circuit to voltage. Contact
service.
Short circuit in tool output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Содержание Robot 185
Страница 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Страница 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Страница 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Страница 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Страница 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Страница 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Страница 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Страница 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...