126
2. Screw the thread part of the accessory over the imager head to fix the accessory.
15.1.4 Technical Specifications
Table 15-1
Specifications
Item
Description
Optimal Viewing
Distance
1" to 14" (2.54cm to 35.56cm) with 8.5mm-
diameter imager head
3/8" to 12" (0.95cm to 30cm) with 5.5mm-
diameter imager head
Resolution
JPG images (640x480)
AVI videos (320 x 240)
Operating Temperature
Main Unit: 0°C to 55°C (ambient)
Cable: -10°C to 70°C
Storage Temperature
-20°C to 75°C (ambient)
Waterproof
Imager head and cable to 1m
Weight
0.3 kg for 8.5 mm diameter imager head
0.2 kg for 5.5 mm diameter imager head