![Autel MaxiSys MS909CV Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/autel/maxisys-ms909cv/maxisys-ms909cv_manual_3020362103.webp)
95
Minimum
: the recorded minimum value of the measurement.
Peak-to-Peak
: the difference between the maximum and minimum values.
Average
: the average value of the measurements.
The waveform in the grid
: a coordinate grid with the X-axis representing the
time duration and the Y-axis representing the amplitude level.
3.
Lower Toolbar
Tap
to select the measurement types
you want:
Icon
Name
Description
AC voltage
Measures the voltage in the electrical circuit.
DC voltage
Resistance
Measures the resistance of the electrical circuit or
the component.
AC current
Measures current amperage by using the optional
current clamp.
DC current
Diode
Conducts a diode test of the electrical circuit.
Connectivity
Determines whether a low impedance exits two
points in the electrical circuit. If the impedance is
less than 100 ohms, the circuit is “closed,”
otherwise, the circuit is “open.”
Tap
Reset
to return to the original state.
NOTE
1.
AC/DC current is measured with clamps, while AC/DC voltage, diode and
connectivity are measured with probes.
2.
When selecting the
Resistance
measurement type, the self-calibration mark
will display beside
Resistance
, indicating the multimeter will return to zero in order
to improve accuracy.
3.
When measuring AC/DC current, different measuring ranges require different
operations of the clamp. Tap
no more
to hide diagram.