94
Figure 8-1
Sample Multimeter Home Screen
1.
Upper Toolbar
Icon
Name
Description
MaxiSys
Home
Returns to MaxiSys Job Menu.
Start/Stop
Button
Starts or stops the multimeter device. Tap to
start the multimeter; Tap to stop the multimeter.
Multimeter
status icon
Indicates the connection status with the battery
tester. A
green “√”
mark means that the tester and
the multimeter are connected; a
red “x”
means that
the device and the tester are not connected.
2.
Main view section
The main view section displays the digital readouts on the top and the waveform in
the grid.
Current Value
: the current value can be the AC voltage, DC voltage,
resistance, frequency, or duty cycle.
Maximum
: the recorded maximum value of the measurement.