![Autel MaxiSys MS909CV Скачать руководство пользователя страница 99](http://html.mh-extra.com/html/autel/maxisys-ms909cv/maxisys-ms909cv_manual_3020362099.webp)
91
8
Multimeter
The multimeter (sold separately) is a multi-function, multi-range measuring instrument.
Connect the multimeter to the B200 device and access its features directly from the
MaxiSys 909CV Home screen to perform basic functions including AC/DC voltage,
resistance measurements, AC/DC current, diode, and connectivity tests. The test results
are displayed in various formats for easy viewing.
8.1 Safety Information
Follow the instructions below to reduce the risk of injury from electric shock and prevent
equipment damage.
Use the multimeter only as specified in this manual.
Do not apply more than the rated voltage between connectors or between any
connector and ground.
Do not input a value beyond the maximum range when measuring. Remember that
the maximum range of this multimeter is 200V.
To prevent injury or death, do not use the multimeter if it appears to be damaged in
any way, and stop use immediately if you are concerned with any abnormal
operations.
To prevent injury or death, never ground yourself when taking electrical
measurements. Isolate yourself from ground by using dry rubber insulating mats to
cover all exposed/grounded metal. Ensure all clothing, including gloves, are dry.
Stand on rubber mats when using the tool.
Use the test leads or probes supplied with the product, or compatible terminals.
Inspect the test leads or probes for damage before use.
When using probes, keep fingers behind the finger guards on the probes.
Use the supplied replacement fuses or specified replacement parts.
Always consider electrical and electronic equipment to be energized (live). Never
assume any equipment is de-energized.
When making electrical connections, connect the common test lead before
connecting the live test lead; when disconnecting, disconnect the live test lead before
disconnecting the common test lead.
When measuring current, turn off circuit power before connecting the multimeter to
the circuit. Remember to place the multimeter in series with the circuit.
After current measurement is finished, turn off the power to the circuit before
removing the test leads and before reconnecting any disconnected wires or devices.
Do not add voltage to the input terminal when measuring resistance.
To avoid electric shock, turn off the power to the component before connecting.