mode").
both local ATEIS net card port A & B connection
broken
check ATEIS net cable
This fault happens when one or more IDA8C's or
IDA8S's over Ateis Net lose the connection.
Check ATEIS net cable
The fireman microphone has an error.
Check backup device
communication and wiring
configuration
The IDA8C/S can't communicate with the
VOX@NET server.
Check VOX@NET communication
1. It shows "Backup Device Offline" when a backup
device can't communicate.
2. It shows "Operation Mode Fail" for:
RU device is turned off.
The incorrect wiring between the RU and the
IDA8.
Check backup device
communication and wiring
configuration
There is an monitoring error in URGP16I160 device
due to the reasons of out of tolerance.
Check URGP16I16O trigger source
The peripheral devices (PSS-AS/PPM-AS/URC-
150AS/...)
can't communicate with the IDA8C/S.
Check remote cable
The URGP 32I device monitor is out of tolerance
Check URGP 32I trigger source
There is a hardware error of peripheral devices,
such as the microphone/speaker on a PSS.
Replace the remote device
The connection with remote such as TerraManager
has lost.
Check remote communication
The remote fault status of the Terra-K/SDM device
with TerraManager.
Check remote status
The file CRC check code fails if the file monitor
option is enabled.
Re-load file again
The Modbus client can't communicate.
Check modbus client
communication
The IDA8 gets the reference value which is too
low.
Check amplifier power, line
A normal amplifier fails and is replaced by the
backup amplifier.
Check normal amplifier power, line
one of local ATEIS net port broken
check ATEIS net cable
One of the global ATEIS net port has broken.
Note: Only for global net IDA8.
Check ATEIS net cable
If using a redundancy unit, the IDA8 will enter the
bypass mode when a Bypass Mode fault occurs. If
not, the IDA8 will enter in that mode only when the
"Bypass Input" line on the rear panel has broken.
Check fault list and "Bypass Input
line"
Major User
Define Fault
The "Fault Define Security" component trigger.
Check trigger source
The "Fault Define Security" component trigger.
Check trigger source
Modan Offline
The Modan client can't communicate.
Check Modan client
communication
All the NTP server can't communicate.
Check NTP server communication
The normal amplifier measure out of tolerance.
Check normal amplifier measure
value
The backup amplifier measure out of tolerance.
Check backup amplifier measure
value
There is some network client attack the machine.
IDA8 will block its communication.
Please check your ethernet
environment
A/B Packet or lost errors in the Ateis Local / Global
Net Card.
Replace the machine
Global ATEIS net card detect unknown
communication so that the port disable, you need
restart machine to recovery it.
check the cable and netcard, if
often appear, please replace
netcard.
Local ATEIS net card detect unknown
communication so that the port disable, you need
restart machine to recovery it.
check the cable and netcard, if
often appear, please replace
netcard.
There is some IDA8 communication is unstable.
Please catch this IDA8 logs and