IDA8 Global-Net User Manual
438
© 2017, ATEÏS, member of PAX ProAV Group
Control Window
Element Description
Invert: Invert the phase of signal.
Mode: The type of filtering.
Slope: The slope of attenuation.
Mute: Mute the filter's module.
Level: The gain of signal.
Frequency: The frequency of cut.
Graphical Control Window
Axis:
o
X: Frequency of output signal(Hz).
o
Y: Level of input signal(dB).
Control Points:
o
Blue: Adjust Level and hi-pass Frequency
or low-pass Frequency of mid band.
o
Yellow: Adjust Level and both hi-pass
Frequency and low-pass Frequency of
mid band.
o
Red: Adjust Level and low band or hi
band.
5.6.5
Hi/Lo Pass
Allow to pass the high/low frequency and attenuate the frequency lower/higher than its cutoff
frequency.