Product Features
109
© 2017, ATEÏS, member of PAX ProAV Group
3.1.10.1.5 Normal Amplifier Monitoring
Settings:
First, in Ateis Studio, right click the
IDA8C/S icon.
When the window [Monitoring(Matrix Mode)-IDA8C/S X ] appears, select the [Normal Amplifier
Settings] page.
Amplifier:
Indicate a row is related to a normal amplifier of a zone.
Monitor:
Enable/disable the normal amplifier monitoring for the selected zone. If the monitoring of a
normal amplifier is disabled, the IDA8C/S will not detect faults of the normal amplifiers.
Tolerance (%):
To determine the boundary of the fault detection for a selected zone. If one of the following
conditions meets the description below, IDA8 will recognize the fault.
o
Measure < (Full Loaded Reference x (100% - Tolerance%))
o
Measure > (Unloaded Reference x (100% + Tolerance%))
Global Tolerance:
Click to change the tolerance setting on [Tolerance%] grid for all the zones of normal amplifier,
which connected to all of the IDA8 processors. If the zone is not been selected on [Global
Tolerance] grid, the tolerance value will not change.
Get Reference:
Get the reference values of the selected zone for further fault detection. Be aware, the hardware