Triggering Mode
The triggering mode defines the rule of
triggering a pulse to output.
Periodic: The interval is the time
between two triggers.
Cyclic: The Occurrence parameter
determines the
cycle
type
of
triggering. There are five types
available:
Hourly/Daily/Weekly/
Monthly/Yearly. It allows the user to
define the interval between cycles by
specifying the parameter of Every N
cycle unit where the cycle unit can be
Hour/Day/Week/Month/Year.
The box lists the Time of Triggering.
You can add or remove the triggering
time in the cycle.
By Excel File
It allows to set the triggering times by using an excel
file. The rules are listed below:
Field A1 is the "Year. Month" for scheduling. Note:
Refer to the format as shown in the picture above.
B1 ~ X1 is the field for time format, there are two
choices:
o
24HR
o
AM/PM
A2 ~ A 32 represents the day of a month.
For each row, B to X fields are the time to be
triggered.
Exception Duration
The "Exception Duration" allows to edit a list
for the exceptions of the triggering. Each
exception consists of a start time and a stop
time. During the exception time all
triggering will be masked.