Product Features
103
© 2017, ATEÏS, member of PAX ProAV Group
Leakage causes the gradual loss of
voltage. Once it is detected, the
IDA8C will open the relay of the
leakage zone.
The following messages will display on the touch panel of the IDA8C and in the Ateis Studio. See
3.1.10.1.2 Open/Short Circuit
Open circuit
The open circuit occurs when a break
exists in a complete conducting pathway.
Once the open circuit is detected, the
IDA8C will open the relay. The following
messages will display on the touch panel
of the IDA8C and in Ateis Studio. See
Short circuit
The short circuit occurs when the
electrical current running
across
separate wires accidentally touch each
other.
Once the short circuit is detected, the
IDA8C will force open the short-circuited
line to protect the circuitry and the
amplifier from the over-current damage.
If you use both line a/b, the IDA8 keeps the
working line continuous, see the picture
below.
The following messages display on the touch panel of the IDA8C and in Ateis Studio. See