IDA8 Global-Net User Manual
90
© 2017, ATEÏS, member of PAX ProAV Group
Troubleshooting: Check the measured value of the normal amplifier.
3.1.9.1.31 Backup AMP Out of Toler
The reference value measured from the backup amplifier is out of tolerance.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
The text messages display at the touch screen of the IDA8C:
"Backup AMP Out of Toler."
"Zone n Backup AMP Gain Too High"
"Zone n Backup AMP Gain Too Low " (Where n = 1~8)
A text message displays at the window [Machine Fault Record] in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Check the measured value of the backup amplifier.
3.1.9.1.32 IP Attack
The local ATEIS net card has failed.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
System Fault LED on the front panel of the IDA8C/S.
o
G. Fault LED on the front panel of the IDA8C/S.
Log:
A text message displays on the touch screen of the IDA8C as:
"Local Netcard Boot Failure"
A text message displays at the [IP Attack] window in Ateis Studio:
A buzzing sound outputs to the monitoring speaker on the front panel of the IDA8C.
Troubleshooting: Please check your ethernet environment.
3.1.9.1.33 NT PHY Error
The system detection of Ateis Local/Global-Net card is broken.
Indication:
LED Indicator: When this error is detected, the following LEDs will light up:
o
G. Fault LED on the front panel of the IDA8C/S.
Log: